24 / 37 page ![]() If VBR > VBR-DIS, the IC starts up and is allowed to switch for 30 msec. After that, if VBR > VBR-OUT (0.4 V, typ.), it continues switching, otherwise it is disabled. From this latter case, if VBR exceeds VBR-IN (0.5 V, typ.) for more than TBR_IN (250 usec, typ.), the IC is allowed to resume switching (brown-in); then, if VBR falls below VBR-OUT for more than TBR_OUT (30 msec, typ.), the IC is disabled (brown-out). The delay times are implemented through up/down counters, to reject temporary disturbances across the line. TBR_OUT is also intended to avoid false protection triggerings due to the input capacitor voltage ripple and to guarantee some hold-up in case of a missing cycle of the input line. Input OVP, brown-in and brown-out conditions can be set connecting a voltage divider across the rectified input mains, iOVP, BR and GND and selecting the resistor values according to the equations below. Equation 10 (10) ROVP=RHV∙ ViOVP_tℎ VIN−OVP−VBR−IN VIN−ON Equation 11 (11) RBR=RHV∙ VBR−IN VIN−ON−VBR−IN In the above formulas, VIN_ONandVIN_OVParetheDCinputvoltageswhichtriggerbrown-inandinput overvoltage protection respectively. The resistor RHV is used to start up the converter and also as part of the voltage divider, once HV and iOVP are connecter together. Its value is arbitrarily selected, with the recommendation to be few tens MΩ at least to minimize the residual consumptions from the input mains. It is worth noting that the thresholds VIN-ON and VIN-OFF (the input voltage values triggering brown-in and brown-out respectively) cannot be set independently but are linked to each other. The DC bus voltage value that turns off the device is thus calculated with the following equation. Equation 12 (12) VIN−OFF=VIN−ON∙VBR−OUT VBR−IN A 10 nF filter capacitor placed between BR pin and GND is necessary to avoid misbehavior of the brown-out logic when a high voltage start-up unit is activated. The brown-in/out function can be disabled connecting the BR to GND. VIPERGAN50 Brown-In and Brown-Out protection DS13888 - Rev 2 page 24/37 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |