| 数据搜索系统,热门电子元器件搜索 |
|
DFE252012F-R47M 数据表(PDF) 51 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
DFE252012F-R47M 数据表(HTML) 51 Page - Analog Devices |
|
51 / 122 page ![]() ● If the VSYS falls below the VUVLO_F (typ 2.7V), all individual buck outputs are disabled immediately (the UVLO_I interrupt asserts) and the output-voltage setting registers (Type F) of all buck phases are reset to their default values (enters buck x output off state). ● If the VIO falls below the VIO_UVLO_F (typ 0.97V), all individual buck outputs are disabled immediately (the VIOFLT_I interrupt asserts) and the output-voltage setting registers (Type F) of all buck phases are reset to their default values (enters buck x output off state). ● If one of the enabled buck outputs falls below the VPOK_F (typ 78% of regulation target), the Mx_POKFLT_I asserts. ● If one of the enabled buck outputs stays below the VPOK_R (typ 82% of regulation target) for longer than the tPOK_TO, only the corresponding output is disabled immediately and the output-voltage setting registers (Type F) of the corresponding buck are reset to their default values. ● If one of the enabled buck outputs falls below the VSCP (typ 20% of regulation target), only the corresponding output is disabled immediately (the Mx_SCFLT_I interrupt asserts) and the output-voltage setting registers (Type F) of the corresponding buck are reset to their default values. ● If the junction temperature exceeds the TSHDN (typ +165°C), all individual buck outputs are disabled immediately (the TSHDN_I interrupt asserts) and the output-voltage setting registers (Type F) of all buck phases are reset to their default values. ● POK and SCP monitoring are not active (masked) during soft-start and soft-stop. When POK fault time-out, SCP, and/or TSHDN fault occurs, the corresponding buck enters either the latch-off or the wait state from the reset state, depending on the AUTO_RSTRT bit setting. ● If AUTO_RSTRT = 0, • The output of the individual buck is forced disabled in latch-off state. • When Mx_EN = EN_Mx = 0 AND TJ ≤ +150°C, the individual buck exits latch-off state and enters buck x output off state. ● If AUTO_RSTRT = 1, • After 500ms of forced-disable in wait state, the individual buck automatically exits wait state and enters buck x output off state, if the junction temperature falls below +150°C (TSHDN = 0). • If the enable logic of individual buck is still valid when it enters buck x output off state, the corresponding buck initiates soft-start as it goes into buck x output on state immediately. MAX77542 16VIN/16A, Quad-Phase High-Efficiency Buck Converter www.analog.com Analog Devices | 51 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |