25 / 380 page ![]() Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 25 2015-08-03 serial interface. The default flow control approach of SIM800 Series is hardware flow control (RTS/CTS flow control), to enable software flow control in the DTE interface and within GSM engine, type the following AT Command: AT+IFC=1, 1 This setting is stored volatile, for use after restart, AT+IFC=1, 1 should be stored to the user profile with AT&W. NOTE: The AT commands listed in the table of AT&W chapter should be stored to user profile with AT&W for use after restart. Most other AT commands in V.25, 3GPP TS 27.005, 3GPP TS 27.007,GPRS will store parameters automatically and can be used after module restart. Ensure that any communications software package (e.g. Hyper terminal) uses software flow control. NOTE: Software Flow control should not be used for data calls where binary data will be transmitted or received (e.g. TCP/IP) as the DTE interface may interpret binary data as flow control characters. 1.6.2 Hardware flow control (RTS/CTS flow control) Hardware flow control achieves the data flow control by controlling the RTS/CTS line. When the data transfer should be suspended, the CTS line is set inactive until the transfer from the receiving buffer has completed. When the receiving buffer is ok to receive more data, CTS goes active once again. To achieve hardware flow control, ensure that the RTS/CTS lines are present on your application platform. 1.7 Definitions 1.7.1 Parameter Saving Mode For the purposes of the present document, the following syntactical definitions apply: NO_SAVE: The parameter of the current AT command will be lost if module is rebooted or current AT command doesn't have parameter. AUTO_SAVE: The parameter of the current AT command will be kept in NVRAM automatically, and it won't be lost if module is rebooted. AT&W_SAVE: The parameter of the current AT command will be kept in NVRAM by sending the command of “AT&W.” |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |