21 / 52 page ![]() Smart Machine Smart Decision SIM800C_Hardware_Design_V1.02 21 2015-4-27 SIM800C can be powered off by AT command “AT+CPOWD=1”. This procedure makes the module log off from the network and allows the software to enter into a secure state to save data before completely shut down. Before the completion of the power off procedure, the module will send URC: NORMAL POWER OFF At this moment, AT commands can not be executed any more. Power off mode can also be indicated by STATUS pin, which is at low level at this time. For detail about AT command “AT+CPOWD”, please refer to document [1]. 4.2.2.3. Over-Voltage or Under-Voltage Power off The module software monitors the VBAT voltage constantly. If the voltage ≤ 3.5V, the following URC will be reported: UNDER-VOLTAGE WARNNING If the voltage ≥ 4.3V, the following URC will be reported: OVER-VOLTAGE WARNNING If the voltage < 3.4V, the following URC will be reported, and the module will be automatically powered off. UNDER-VOLTAGE POWER OFF If the voltage > 4.4V, the following URC will be reported, and the module will be automatically powered off. OVER-VOLTAGE POWER OFF At this moment, AT commands can not be executed any more. Power off mode can also be indicated by STATUS pin, which is at low level at this time. 4.2.2.4. Over-Temperature or Under-Temperature Power off The module will constantly monitor the temperature of the module, If the temperature ≥ +80℃, the following URC will be reported: +CMTE: 1 If the temperature ≤ -30℃, the following URC will be reported: +CMTE:-1 If the temperature > +85℃, the following URC will be reported, and the module will be automatically powered off. +CMTE: 2 If the temperature < -40℃, the following URC will be reported, and the module will be automatically powered off. +CMTE:-2 At this moment, AT commands can not be executed any more. Power off mode can also be indicated by STATUS pin, which is at low level at this time. Note:The default temperature detect is disable, AT command “AT+CMTE” could be used to read the temperature when the module is running.For details please refer to document [1]. 4.2.2.5. Restart SIM800C by PWRKEY Pin: When the module works normally, if the customer wants to restart the module, follow the procedure below: 1) Power off the module. 2) Wait for at least 800ms after STATUS pin changed to low level. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |