| 数据搜索系统,热门电子元器件搜索 |
|
TMD2621 数据表(PDF) 35 Page - OSRAM GmbH |
|
|
|||||||||||||||||||||||||||||
TMD2621 数据表(HTML) 35 Page - OSRAM GmbH |
|
35 / 59 page ![]() Page 34 Datasheet, Public Document Feedback [v4-00] 2023-Apr-12 TMD2621 − Register O ver view CALIB Register (Address 0xD7) Figure 49: CALIB Register Proximity response in systems with electrical and optical crosstalk may be improved by using the calibration feature. Optical crosstalk is caused when the photodiode receives a portion of the VCSEL IR, which was unintentionally reflected by a surface other than the target. Electrical offset is caused by electrical disturbance in the sensor AFE, and influences the proximity result as well. Before starting the calibration, it is required to set PEN, AEN and PON to 0 to bring the state machine idle, and set DISABLE_APC to 1 to disable the auto pulse control. The calibration target, BINSRCH_TARGET, needs to be configured to a desired value, the calibration routine adjusts the value in POFFSET /POFFSET_SIGN until the proximity result is as close to the BINSRCH_TARGET as possible. The calibration needs to run with the same settings as regular proximity measurement, such as PPULSE, PPULSE_LEN, PGAIN, PGAIN2, PLDRIVE0. If PTIME_IN_CALIB is enabled, the same PTIME used for regular proximity measurement is also enabled during the calibration. If OFFCAL_ENAB_AVG is enabled, the hardware averaging as selected with PROX_DATA_AVG is enabled as well during the calibration. The calibration needs to run 9 proximity measurement cycles. If every cycle of the 9 cycles needs to be synchronized to the VSYNC signal with PSD delay, PROX_CAL_VSYNC_EN has to be enabled. After all the settings properly configured, PON needs to be enabled again Addr: 0xD7 CALIB Bit Bit Name Default Access Bit Description 7 OFFCAL_ENAB_AVG 0 RW Enables proximity hardware averaging as selected with PROX_DATA_AVG during calibration. 0 = No hardware averaging; 1 = Hardware averaging enabled. 6 Reserved 0 RW Reserved. Must be set to default value. 5 ELECTRICAL_ CALIBRATION 0RW Selects proximity calibration type. 0 = Electrical and optical crosstalk; 1 = Electrical crosstalk only. 4PTIME_IN_CALIB 0 RW Enables PTIME during calibration. Useful when averaging is enabled. 0 = PTIME ignored during calibration; 1 = PTIME enabled during calibration. 3:1 Reserved 000 RW Reserved. Must be set to default value. 0 START_OFFSET_CAL 0 RW Set to 1 to start a calibration sequence. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |