8 / 33 page ![]() PCA9673_1 © NXP B.V. 2007. All rights reserved. Product data sheet Rev. 01 — 1 February 2007 8 of 33 NXP Semiconductors PCA9673 Remote 16-bit I/O expander for Fm+ I2C-bus with interrupt and reset 7.2.1 Software Reset The Software Reset Call allows all the devices in the I2C-bus to be reset to the power-up state value through a specific formatted I2C-bus command. To be performed correctly, it implies that the I2C-bus is functional and that there is no device hanging the bus. The Software Reset sequence is defined as following: 1. A START command is sent by the I2C-bus master. 2. The reserved General Call I2C-bus address ‘0000 000’ with the R/W bit set to 0 (write) is sent by the I2C-bus master. 3. The PCA9673 device(s) acknowledge(s) after seeing the General Call address ‘0000 0000’ (00h) only. If the R/W bit is set to 1 (read), no acknowledge is returned to the I2C-bus master. 4. Once the General Call address has been sent and acknowledged, the master sends 1 byte. The value of the byte must be equal to 06h. a. The PCA9673 acknowledges this value only. If the byte is not equal to 06h, the PCA9673 does not acknowledge it. If more than 1 byte of data is sent, the PCA9673 does not acknowledge any more. 5. Once the right byte has been sent and correctly acknowledged, the master sends a STOP command to end the Software Reset sequence: the PCA9673 then resets to the default value (power-up value) and is ready to be addressed again within the specified bus free time. If the master sends a Repeated START instead, no reset is performed. The I2C-bus master must interpret a non-acknowledge from the PCA9673 (at any time) as a ‘Software Reset Abort’. The PCA9673 does not initiate a reset of its registers. The unique sequence that initiates a Software Reset is described in Figure 12. 7.2.2 Device ID (PCA9673 ID field) The Device ID field is a 3-byte read-only (24 bits) word giving the following information: • 8 bits with the manufacturer name, unique per manufacturer (for example, NXP Semiconductors). • 13 bits with the part identification, assigned by manufacturer, the 7 MSBs with the category ID and the 6 LSBs with the feature ID (for example, PCA9673 16-bit quasi-output I/O expander). Fig 12. Software Reset sequence 002aac307 0 0 0 0 0 0 0 A S 0 SWRST Call I2C-bus address START condition R/W acknowledge from slave(s) 0 0 0 0 1 1 0 0 SWRST data = 06h A acknowledge from slave(s) P PCA9673 is(are) reset. Registers are set to default power-up values. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |