HYS64T64020HDL 数据表(PDF) 23 Page - Qimonda AG

部件名 HYS64T64020HDL
功能描述  200 Pin Small-Outlined DDR2 SDRAMs Modules
PDF  69 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
制造商  QIMONDA [Qimonda AG]
网页  http://www.qimonda.com
标志 QIMONDA - Qimonda AG

HYS64T64020HDL 数据表(HTML) 23 Page - Qimonda AG

Back Button HYS64T64020HDL Datasheet HTML 19Page - Qimonda AG HYS64T64020HDL Datasheet HTML 20Page - Qimonda AG HYS64T64020HDL Datasheet HTML 21Page - Qimonda AG HYS64T64020HDL Datasheet HTML 22Page - Qimonda AG HYS64T64020HDL Datasheet HTML 23Page - Qimonda AG HYS64T64020HDL Datasheet HTML 24Page - Qimonda AG HYS64T64020HDL Datasheet HTML 25Page - Qimonda AG HYS64T64020HDL Datasheet HTML 26Page - Qimonda AG HYS64T64020HDL Datasheet HTML 27Page - Qimonda AG Next Button
Zoom Inzoom in Zoom Outzoom out
 23 / 69 page
background image
HYS64T[32/64/128]xxxHDL-[25F/2.5/3/3S/3.7/5]-B
SO-DIMM DDR2 SDRAM Module
Internet Data Sheet
Rev. 1.12, 2007-10
23
03292006-5LTN-QML0
1) For details and notes see the relevant Qimonda component data sheet
2)
V
DDQ = 1.8 V ± 0.1V; VDD = 1.8 V ± 0.1 V.
3) Timing that is not specified is illegal and after such an event, in order to guarantee proper operation, the DRAM must be powered down
and then restarted through the specified initialization sequence before normal operation can continue.
4) Timings are guaranteed with CK/CK differential Slew Rate of 2.0 V/ns. For DQS signals timings are guaranteed with a differential Slew
Rate of 2.0 V/ns in differential strobe mode and a Slew Rate of 1 V/ns in single ended mode.
5) The CK / CK input reference level (for timing reference to CK / CK) is the point at which CK and CK cross. The DQS / DQS, RDQS / RDQS,
input reference level is the crosspoint when in differential strobe mode. component
6) Inputs are not recognized as valid until
V
REF stabilizes. During the period before VREF stabilizes, CKE = 0.2 x VDDQ is recognized as low.
7) The output timing reference voltage level is
V
TT. component datasheet
8) For each of the terms, if not already an integer, round to the next highest integer.
t
CK refers to the application clock period. WR refers to
the WR parameter stored in the MR.
9) The clock frequency is allowed to change during self-refresh mode or precharge power-down mode.
10) For timing definition, refer to the Component data sheet.
11) Consists of data pin skew and output pattern effects, and p-channel to n-channel variation of the output drivers as well as output Slew Rate
mis-match between DQS / DQS and associated DQ in any given cycle.
12) MIN (
t
CL, tCH) refers to the smaller of the actual clock low time and the actual clock high time as provided to the device (i.e. this value can
be greater than the minimum specification limits for
t
CL and tCH).
13) The
t
HZ, tRPST and tLZ, tRPRE parameters are referenced to a specific voltage level, which specify when the device output is no longer driving
(
t
HZ, tRPST), or begins driving (tLZ, tRPRE). tHZ and tLZ transitions occur in the same access time windows as valid data transitions.These
parameters are verified by design and characterization, but not subject to production test.
14) The Auto-Refresh command interval has be reduced to 3.9 µs when operating the DDR2 DRAM in a temperature range between 85
°C
and 95
°C.
15) 0 °C
≤
T
CASE ≤ 85 °C.
16) 85
°C <
T
CASE ≤ 95 °C.
17) A maximum of eight Auto-Refresh commands can be posted to any given DDR2 SDRAM device
18) The
t
RRD timing parameter depends on the page size of the DRAM organization.
19) The maximum limit for the
t
WPST parameter is not a device limit. The device operates with a greater value for this parameter, but system
performance (bus turnaround) degrades accordingly.
20) Minimum
t
WTR is two clocks when operating the DDR2-SDRAM at frequencies ≤ 200 ΜΗz.
21) User can choose two different active power-down modes for additional power saving via MRS address bit A12. In “standard active power-
down mode” (MR, A12 = “0”) a fast power-down exit timing
t
XARD can be used. In “low active power-down mode” (MR, A12 =”1”) a slow
power-down exit timing
t
XARDS has to be satisfied.
22) WR must be programmed to fulfill the minimum requirement for the
t
WR timing parameter, where WRMIN[cycles] = tWR(ns)/tCK(ns) rounded
up to the next integer value.
t
DAL = WR + (tRP/tCK). For each of the terms, if not already an integer, round to the next highest integer. tCK
refers to the application clock period. WR refers to the WR parameter stored in the MRS.
Exit Self-Refresh to Read command
t
XSRD
200
—
200
—
t
CK
Write recovery time for write with
Auto-Precharge
WR
t
WR/tCK
t
WR/tCK
t
CK
22)
Parameter
Symbol
DDR2–533
DDR2–400
Unit
Notes2)3)
4)5)6)7)
Min.
Max.
Min.
Max.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69


数据表 下载

Go To PDF Page


链接网址



ALLDATASHEET是否为您带来帮助?  [ DONATE ] 

关于 Alldatasheet   |   广告服务   |   联系我们   |   隐私政策   |   数据表链接    |   链接交换   |   制造商名单
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com