| 数据搜索系统,热门电子元器件搜索 |
|
HYS64T64020HDL 数据表(PDF) 25 Page - Qimonda AG |
|
|
|||||||||||||||||||||||||||||
HYS64T64020HDL 数据表(HTML) 25 Page - Qimonda AG |
|
25 / 69 page ![]() HYS64T[32/64/128]xxxHDL-[25F/2.5/3/3S/3.7/5]-B SO-DIMM DDR2 SDRAM Module Internet Data Sheet Rev. 1.12, 2007-10 25 03292006-5LTN-QML0 3.4 I DD Specifications and Conditions List of tables defining I DD Specifications and Conditions. TABLE 18 I DD Measurement Conditions 2) ODT turn off time min. is when the device starts to turn off ODT resistance. ODT turn off time max is when the bus is in high impedance. Both are measured from t AOFD. Both are measured from tAOFD, which is interpreted differently per speed bin. For DDR2-400/533, tAOFD is 12.5 ns (= 2.5 x 5 ns) after the clock edge that registered a first ODT HIGH if t CK = 5 ns. Parameter Symbol Note1)2) 3)4)5) Operating Current 0 One bank Active - Precharge; t CK = tCK.MIN, tRC = tRC.MIN, tRAS = tRAS.MIN, CKE is HIGH, CS is HIGH between valid commands. Address and control inputs are SWITCHING, Databus inputs are SWITCHING. I DD0 Operating Current 1 One bank Active - Read - Precharge; I OUT = 0 mA, BL = 4, tCK = tCK.MIN, tRC = tRC.MIN, tRAS = tRAS.MIN, t RCD = tRCD.MIN, AL = 0, CL = CLMIN; CKE is HIGH, CS is HIGH between valid commands. Address and control inputs are SWITCHING, Databus inputs are SWITCHING. I DD1 6) Precharge Standby Current All banks idle; CS is HIGH; CKE is HIGH; t CK = tCK.MIN; Other control and address inputs are SWITCHING, Databus inputs are SWITCHING. I DD2N Precharge Power-Down Current Other control and address inputs are STABLE, Data bus inputs are FLOATING. I DD2P Precharge Quiet Standby Current All banks idle; CS is HIGH; CKE is HIGH; t CK = tCK.MIN; Other control and address inputs are STABLE, Data bus inputs are FLOATING. I DD2Q Active Standby Current Burst Read: All banks open; Continuous burst reads; BL = 4; AL = 0, CL = CLMIN; tCK = tCK.MIN; t RAS = tRAS.MAX, tRP = tRP.MIN; CKE is HIGH, CS is HIGH between valid commands. Address inputs are SWITCHING; Data Bus inputs are SWITCHING; I OUT = 0 mA. I DD3N Active Power-Down Current All banks open; t CK = tCK.MIN, CKE is LOW; Other control and address inputs are STABLE, Data bus inputs are FLOATING. MRS A12 bit is set to LOW (Fast Power-down Exit); I DD3P(0) Active Power-Down Current All banks open; tCK = tCK.MIN, CKE is LOW; Other control and address inputs are STABLE, Data bus inputs are FLOATING. MRS A12 bit is set to HIGH (Slow Power-down Exit); I DD3P(1) Operating Current - Burst Read All banks open; Continuous burst reads; BL = 4; AL = 0, CL = CLMIN; tCK = tCKMIN; tRAS = tRASMAX; t RP = tRPMIN; CKE is HIGH, CS is HIGH between valid commands; Address inputs are SWITCHING; Data bus inputs are SWITCHING; I OUT = 0mA. I DD4R 6) Operating Current - Burst Write All banks open; Continuous burst writes; BL = 4; AL = 0, CL = CLMIN; tCK = tCK.MIN; t RAS = tRAS.MAX., tRP = tRP.MAX; CKE is HIGH, CS is HIGH between valid commands. Address inputs are SWITCHING; Data Bus inputs are SWITCHING; I DD4W Burst Refresh Current t CK = tCK.MIN., Refresh command every tRFC = tRFC.MIN interval, CKE is HIGH, CS is HIGH between valid commands, Other control and address inputs are SWITCHING, Data bus inputs are SWITCHING. I DD5B |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |