| 数据搜索系统,热门电子元器件搜索 |
|
PM6680 数据表(PDF) 31 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
PM6680 数据表(HTML) 31 Page - STMicroelectronics |
|
31 / 49 page ![]() PM6680 Device description 31/49 7.12 Monitoring and protections 7.12.1 Power good signals The PM6680 provides three independent power good signals: one for each switching section (PGOOD1/PGOOD2). PGOOD1/PGOOD2 signals are low if the output voltage is out of ±10% of the designed set point or during the soft-start, the soft end and when the device works in standby and shutdown mode. 7.12.2 Thermal protection The PM6680 has a thermal protection to preserve the device from overheating. The thermal shutdown occurs when the die temperature goes above +150°C. In this case all internal circuitry is turned off and the power sections are turned off after the discharge mode. A power on reset or a toggle on the SHDN pin is necessary to restart the device. 7.12.3 Overvoltage protection When the switching output voltage is about 115% of its nominal value, a latched overvoltage protection occurs. In this case, the synchronous rectifier immediately turns on while the high-side MOSFET turns off. The output capacitor is rapidly discharged and the load is preserved from being damaged. The overvoltage protection is also active during the soft start. Once an overvoltage protection has been detected, a toggle on SHDN, EN1/EN2 pins or a power on reset is necessary to exit from the latched state. 7.12.4 Undervoltage protection When the switching output voltage is below 70% of its nominal value, a latched undervoltage protection occurs. In this case the switching section is immediately disabled and both switches are open. The controller enters in soft end mode and the output is eventually kept to ground, turning low side MOSFET on. The undervoltage circuit protection is enabled only at the end of the soft-start. Once an overvoltage protection has been detected, a toggle on SHDN, EN1/EN2 pin or a power on reset is necessary to clear the undervoltage fault and starts with a new soft-start phase. Table 9. Protections and operatives modes Mode Conditions Description Overvoltage protection OUT1/OUT2 > 115% of the nominal value LGATE1/LGATE2 pin is forced high, LDO5 remains active. Exit by a power on reset or toggling SHDN or EN1/EN2 Undervoltage protection OUT1/OUT2 < 70% of the nominal value LGATE1/LGATE2 is forced high after the soft end mode, LDO5 remains active. Exit by a power on reset or toggling SHDN or EN1/EN2 Thermal shutdown TJ > +150ºC All circuitry off. Exit by a POR on VIN or toggling SHDN. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |