| 数据搜索系统,热门电子元器件搜索 |
|
L99CL01XP 数据表(PDF) 13 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
L99CL01XP 数据表(HTML) 13 Page - STMicroelectronics |
|
13 / 60 page ![]() DocID023902 Rev 4 13/60 L99CL01XP Functional description 2.6 Limp input The fail mode (limp home mode) of the component is activated by this digital input port in addition to the internal fail mode detection circuit of the device (see Section 3.2.5: Fail Mode). The limp home mode is activated by a logic [1] signal at the input. During limp home mode the outputs are directly controlled by the inputs IN1, IN2, IN3, IN5, IN6, IN7. and the PWM module is disabled. The limp input has an internal pull down resistor. 2.7 Control, protection and diagnosis 2.7.1 Smart switches and gate drivers The smart switches are controlled by dedicated gate driver including: Output pulse shaping Overload protection incl. protection against low resistive short circuit and shorts with line inductance Over temperature protection incl. over temperature warning signals The outputs are switched with active pulse shaping to provide an excellent EMC performance of the system. Therefore the output current of each driver is monitored by a feedback loop in order to control the switching speed of the output. Thereby a compromise between edge shaping and propagation delay of the switch is necessary to achieve low duty cycle values (3% < dc < 97% @ 250Hz). 2.7.2 PWM module PWM control In order to minimize the microcontroller’s work load, a synchronous PWM module is integrated. The frequency and timing is derived from the PWMclock input (see Section 2.5.1: PWMCLK input), the control of the PWM module is provided by SPI and INx (see Section : PWM control) The smart switches can be controlled in the range of 0%...100% with a resolution of 1/256%. The value 00h in the Individual and Global PWM registers refers to OFF state, the value FFh refers to 255/256 ON state of the switches. The PWM timing includes 4 programmable switching phases (0°, 90°, 180° and 270°). The phase can be controlled individually for each channel depending on the channel control registers [#1~#8 D10~D9] The synchronization of the switching phases between different devices is provided by the PWMsync bit in Initialisation register [#0:D8]. To guarantee a proper generation and smooth PWM duty cycle change via SPI the duty cycle start point is defined by the internal PWM counter zero crossing. Therefore every SPI programmed duty cycle change and duty cycle source change will not take effect till the PWM counter zero crossing is reached (this strategy is also known as buffered PWM). Setting the output to OFF or 100% ON, the setting will occur immediately and independently from PWM counter. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |