| 数据搜索系统,热门电子元器件搜索 |
|
L99CL01XP 数据表(PDF) 43 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
L99CL01XP 数据表(HTML) 43 Page - STMicroelectronics |
|
43 / 60 page ![]() DocID023902 Rev 4 43/60 L99CL01XP SPI interface The current sense is active and the Kfactor is the one, which corresponds to the Low Ron setting. Auto restart feature The auto restart feature is used to control the smart switches in case of overcurrent, under or over voltage failure conditions to provide a high availability of the outputs even when no supervising intelligence of the microcontroller is available (Fail Mode). Auto restart is enabled in case of Overcurrent condition (OCx) of the corresponding channel Under or over voltage condition (UVx or OVx) on the corresponding supply line In case of OC, UV or OV the corresponding output or outputs are deactivated. In case of OC failure the output returns to Fail Mode direct drive after a dedicated time (tautorestart = 100 ms). During this ON phase the diagnosis is restarted. When the failure is still present and the channel is turned off again. Therefore the output stays in this cyclic loop as long as the failure is present. In case of UV or OV the diagnosis is continuously running. After removing the failure condition (UV or OV) the switch returns to Fail Mode direct drive after a dedicated time within tautorestart. In case of over temperature shutdown (OTS) the switch enters “Latch OFF” state which can only be removed by a mode change to “Normal Mode” or “Standby” (seeChapter 3.2: Operating modes). PWMEN/INSEL, #11-13 As before Fail mode No No(2) Global PWMx, #1-2 As before Fail mode No No(2) 1. The PWM unit is disabled and the state of OUTx is according to the corresponding INx,x=1-3,5-7 regardless to the content of these registers. OUT4 and OUT8 are OFF. 2. While entering the Fail Mode, the content of the Mode Control register is reset to its default value and the device behaves accordingly: the Rdson of the Output is set to the low value and the overcurrent blank time is enabled. This control register is write-protected in Fail Mode. Table 17. Control registers in Fail Mode Control registers Content during transition to Fail Mode Write protection Valid content |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |