Back Button L99CL01XP Datasheet HTML 38Page - STMicroelectronics L99CL01XP Datasheet HTML 39Page - STMicroelectronics L99CL01XP Datasheet HTML 40Page - STMicroelectronics L99CL01XP Datasheet HTML 41Page - STMicroelectronics L99CL01XP Datasheet HTML 42Page - STMicroelectronics L99CL01XP Datasheet HTML 43Page - STMicroelectronics L99CL01XP Datasheet HTML 44Page - STMicroelectronics L99CL01XP Datasheet HTML 45Page - STMicroelectronics L99CL01XP Datasheet HTML 46Page - STMicroelectronics Next Button
Zoom Inzoom in Zoom Outzoom out
 42 / 60 page
background image
SPI interface
L99CL01XP
42/60
DocID023902 Rev 4
3.2.5
Fail Mode
The L99CL01XP offers the possibility to control OUT1-3 and OUT5-7 in case of fail safe
event by the corresponding INx pins (refer to Table 15)
The Fail Mode is activated if one of the conditions listed in the following table occurs. The
operation in Fail Mode is reported by the status bit Fail Safe (any Status Register, bit11) and
by one of the status bits: VDDUV, SPIF, WDCERR, LIMP, depending on the cause of the
activation of the Fail Mode.
In this mode, the device’s SPI is active unless a VDD undervoltage occurs.
The control registers behaves as described in the Table 17. The content of the status
registers are kept during the transition to Fail Mode.
Table 15. Mapping between the input pins and the outputs in Fail Mode
Pin
Corresponding output
IN1
OUT1
IN2
OUT2
IN3
OUT3
IN5
OUT5
IN6
OUT6
IN7
OUT7
Table 16. Events leading to Fail Mode
Event
Related status bit
Delay to Fail Mode
VDD undervoltage
VDDUV
After tVDD_UV
SPI Failure
SPIF
Immediate
Watchdog check error
WDCERR
After WDTimeout
LIMP = High
LIMP
After tLIMP
During Active Mode, EN goes from High to Low
while one of the INx,x= 1-3, 5-6 is High
(1)
1.
When this condition occurs, the device prevents the refresh of the WD toggle bit, leading to a Watchdog
timeout failure. As long as EN = Low, the refresh of the WD is blocked and the device cannot go to Normal
Mode.
WDCERR
After WDTimeout
Table 17. Control registers in Fail Mode
Control registers
Content during transition
to Fail Mode
Write protection
Valid content
Initialization, #0
As before Fail mode
No
Yes
CHx Control, #1-8
As before Fail mode
No
No(1)
Mode Control, #9
Reset to default value
Yes(2)
Yes
OUT enable, #10
As before Fail mode
No
No(2)



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60


数据表 下载

Go To PDF Page


链接网址



ALLDATASHEET是否为您带来帮助?  [ DONATE ] 

关于 Alldatasheet   |   广告服务   |   联系我们   |   隐私政策   |   数据表链接    |   链接交换   |   制造商名单
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com