| 数据搜索系统,热门电子元器件搜索 |
|
L99CL01XP 数据表(PDF) 41 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
L99CL01XP 数据表(HTML) 41 Page - STMicroelectronics |
|
41 / 60 page ![]() DocID023902 Rev 4 41/60 L99CL01XP SPI interface Wakeup sources are as follows: ENABLE input signals IN1, IN2, IN3, IN5, IN6, IN7 toggle signal: this signal is an OR combination from all input signals by a retriggerable mono stable. It keeps the device active for a dedicated time (ttoggle) after the last negative edge at any input signal IN1, IN2, IN3, IN5, IN6, IN7: Figure 5. Toggle signal When ENABLE is off but another wakeup source is still active this can be monitored by the PWMCLK(WAKE) pin which is an active high output during pending WAKE. By leaving the FailMode all internal registers will be reset to default state. 3.2.3 Cold start – power up reset The cold start sequence describes the power up and the startup of the device. When VS is in the specified ranges and the INx or the ENABLE pin are on a logical [0] level the device is in STANDBY. When INx or ENABLE change their levels to logical [1] the internal EN for the power on reset circuit (POR) and the oscillator (OSC) will be set to [1] and the two blocks will be enabled. The device is started. The internal POR is released and the oscillator is running. The internal registers are reset. to their default value and the device enter NORMAL MODE 3.2.4 Normal Mode The device enters Normal mode: either from Standby Mode if VDD > VDDUV, LIMP =Low, and EN goes from Low to High. Refer to Section 3.2.3: Cold start – power up reset or from Fail Mode, refer to Section 3.2.6: Warm start – (Transition from FailMode to Normal over Internal Reset) In Normal mode, the SPI is active and the output stages are controlled by the SPI and the INx settings. The SPI diagnostics and the CurrentSense pin are both available. The protections are fully functional. Normal mode is left with the following conditions: VDD falls below VDDUV A watchdog failure occurs: wrong toggling of WD Bit or No toggling of the WD bit for a duration exceeding TWD EN goes Low An SPI failure occurs LIMP goes to Low t_toggle IN1 or IN2 or IN3 or IN5 or IN 6 or IN7 toggle |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |