21 / 29 page ![]() Device Operation (Continued) control register instead of the multi-function I/O port, bit 7, the I/O port bit must be remapped to another bit in the control registers. Remapping to a read-only function is recom- mended to avoid possible conflicting data being written into the remapped location. The Pass/Fail bit indicates the result of running the built-in self-test. This bit is a logic-1 for a pass condition. The bit is mapped to I/O port bit 6 in the default condition. VIDEO INFO 0 REGISTER (Address 0Eh) The NSP (New Sync Position) bit indicates that a new or out-of-place TRS character has been detected in the input data. This bit is set to a logic-1 and remains set for at least one horizontal line period or unless re-activated by a subse- quent new or out-of-place TRS. It is reset by an EAV TRS character. The EAV (end of active video) and SAV (start of active video) bits track the occurrence of the corresponding TRS charac- ters. Lock Detect is registered as a control signal and is a logic-1 when the PLL is locked and a valid format has been de- tected. This bit may be programmed as an output on the multi-function I/O port. This bit is mapped to I/O port bit 4 in the default condition. This function also includes logic to check the stability of the device after the digital logic reset is released following PLL lock. If the system is not fully stable, the logic is automatically reset. LOCK DETECT also com- bines the function of indicating that the CLC030 has de- tected the video format being received. This format detect function involves determination of the major raster param- eters such as line length, number of video lines in a frame, and so forth. This is done so that information like line num- bering can be correctly inserted. The PLL itself will have locked in about 50 microseconds (HD rates, 150 microsec- onds for SD) or less; however, resolution of all raster param- eters may take the majority of a frame. The VPG Filter Enable bit when set enables operation of the Video Pattern Generator filter. Operation of this filter causes the insertion of transition codes in the chroma and luma data of color bar test patterns where these patterns change from one bar to the next. This filter reduces the magnitude of out-of-band frequency products which can be produced by abrupt transitions in the chroma and luma data when fed to D-to-A converters and picture monitors. The default condi- tion of this bit is reset (off). A method by which the occurrence of pathological data patterns can be prevented has been proposed for SD for- mats. The CLC030 implements this process for SD formats. The Dither Enable and Vertical Dither Enable bits control operation of pseudo-random dithering applied to the two LSBs of the video data. Dithering is applied to active video data when the Dither Enable bit is set. When the Vertical Dither Enable bit is set, dithering is applied to that portion of the video line corresponding to active video for lines in the vertical blanking interval. I/O PIN 0 THROUGH 7 CONFIGURATION REGISTERS (Addresses 0Fh through 16h) The Multi-function I/O Bus Pin Configuration registers are used to map the bits of the multi-function I/O port to selected bits of the Configuration and Control Registers. Table 6 details the available Configuration and Control register bit functions that may be mapped to the port and their corre- sponding mapping addresses. Pin # SEL[5] in each register indicates whether the port pin is input or output. The port pin will be an input when this bit is set and an output when reset. Input-only functions may not be configured as outputs and vice versa. The remaining lower-order five address bits dis- tinguish the particular function. Example: Program, via the AD port, I/O port bit 0 as output for the CRC Luma Error bit in the control registers. 1. Set ANC/CTRL to a logic-low. 2. Set RD/WR to a logic-low. 3. Present 00Fh to AD[9:0] as the I/O PIN 0 CONFIG register address. 4. Toggle ACLK. 5. Present 310h to AD[9:0] as the register data, the bit address of the CRC Luma Error bit in the control regis- ters. 6. Toggle ACLK. TEST MODE 0 REGISTER (Address 55h) The four bits of this register are intended for use as test mode functions. They are not normal operating modes. The bits may be set (enabled) or reset (disabled) by writing to the register. Reading this register sets (enables) all bits to their default ON condition. The Scrambler_Enable bit enables operation of the SMPTE scrambler function. This bit is normally ON. The NRZI_Enable bit enables operation of the NRZ-to-NRZI conversion function. This bit is normally ON. The LSB_Clipping bit enables operation of the LSB clipping function. This bit is normally ON. The Sync_Detect_Enable bit enables operation of the TRS detector function. This bit is normally ON. www.national.com 21 |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |