| 数据搜索系统,热门电子元器件搜索 |
|
CLC030 数据表(PDF) 13 Page - National Semiconductor (TI) |
|
|
|
|||||||||||||||||||||||||||||
CLC030 数据表(HTML) 13 Page - National Semiconductor (TI) |
|
13 / 29 page ![]() Device Operation (Continued) supplied power via external low-pass filters, if desired. PLL acquisition time is less than 200µs @ 1,485 Mbps. The VCO halts when the V CLK signal is not present or is inactive. A LOCK DETECT indicator function is available as a bit in the VIDEO INFO 0 control registers. LOCK DETECT is a logic-1 when the PLL is locked and a valid format has been detected. It can be assigned as an output on the multifunc- tion I/O port. By default LOCK DETECT is assigned as I/O Port bit 4 after power-on or reset . This function also includes logic to check the stability of the device after the digital logic reset is released following PLL lock. If the system is not fully stable, the logic is automatically reset. LOCK DETECT also combines the function of indicating that the CLC030 has detected the video format being received. This format detect function involves determination of the major raster param- eters such as line length, number of video lines in a frame, and so forth. This is done so that information like line num- bering can be correctly inserted. The PLL itself will have locked in 200 microseconds (HD rates) or less. However, resolution of all raster parameters may take the majority of a frame. SERIAL DATA OUTPUT DRIVER The serial data outputs provide low-skew complimentary or differential signals. The output buffer is a current-mode de- sign and is intended to drive AC-coupled and terminated, 75 Ω coaxial cables. The driver automatically adjusts its out- put slew rate depending upon the data rate being processed. Output levels are 800 mV P-P ±10% into 75 Ω AC-coupled loads. The 75 Ω resistors connected to the SDO outputs function both as drain-load and back-matching resistors. Series back-matching resistors are not used with this output type. The serial output level is controlled by the value of R REFLVL and R REFPRE connected to pin 53 and pin 52, respectively. The R REFLVL resistor sets the peak-to-peak level of the output signal to the required SMPTE nominal level. The R REFPRE resistor sets the value of a pre-emphasis current which is active during the transition times of the HD-rate output signal. The value of R REFLVL is normally 4.75 K Ω, ±1%. The value of R REFPRE is normally 4.75 K Ω, ±1%. The voltage present at these pins is approximately +1.3Vdc. The transition times of this output buffer design automatically adjust and are different for the HD and SD data rate condi- tions. The output buffer is quiescent when the device is in an out-of-lock condition. The output will become active after the PLL is locked and a valid format has been detected. Sepa- rate power feeds are provided for the serial output driver: V SSSD, pins 54, 55, and 59; VDDSD, pin 51; and VDDLS, pin 57. CAUTION: This output buffer is not designed or specified for driving 50 Ω or other impedance loads. POWER SUPPLIES, POWER-ON-RESET AND RESET INPUT The CLC030 requires two power supplies, 2.5V for the core logic functions and 3.3V for the I/O functions. The supplies must be applied to the device in proper sequence. The 3.3V supply must be applied prior to or coincident with the 2.5V supply. Application of the 2.5V supply must not precede the 3.3V supply. It is recommended that the 3.3V supply be configured or designed so as to control application of the 2.5V supply in order to satisfy this sequencing requirement. The CLC030 has an automatic, power-on-reset circuit. Re- set initializes the device and clears TRS detection circuitry, all latches, registers, counters and polynomial generators, sets the EDH/CRC characters to 00h and disables the serial output. Table 1 lists the initial conditions of the configuration and control registers. An active-HIGH-true, manual reset input is available at pin 64. The reset input has an internal pull-down device and may be considered inactive when unconnected. Important: When power is first applied to the device or following a reset, the Ancillary and Control Data Port must be initialized to receive data. This is done by toggling ACLK three times. TEST PATTERN GENERATOR (TPG) AND BUILT-IN SELF-TEST (BIST) The CLC030 includes a built-in test pattern generator (TPG). Four test pattern types are available for all data rates, all HD and SD formats, NTSC and PAL standards, and 4x3 and 16x9 raster sizes. The test patterns are: flat-field black, PLL pathological, equalizer (EQ) pathological and a 75%, 8-color vertical bar pattern. The pathologicals follow the recommendations of SMPTE RP 178-1996 regarding the test data used. The color bar pattern has optional bandwidth limiting coding in the chroma and luma data transitions be- tween bars. The VPG FILTER ENABLE bit in the VIDEO INFO 0 control register enables the color bar filter function. The default condition of VPG FILTER ENABLE is OFF. The TPG also functions as a built-in self-test (BIST) which can verify device functionality. The BIST function performs a comprehensive go/no-go test of the device. The test may be run using any of the HD color bar test patterns or one of two SD test patterns, either a 270 Mb/s NTSC full-field color bar or a PAL PLL pathological, as the test data pattern. Data is supplied internally in the input data register, processed through the device and tested for errors using either the EDH system for SD or the CRC system for HD. A go/no-go indi- cation is logged in the Pass/Fail bit of the TEST 0 control register set. This bit may be assigned as an output on the multifunction I/O port. TPG and BIST operation is initiated by loading the code for the desired test pattern into the Test Pattern Select [5:0] bits of the TEST 0 register. Table 5 gives the available test patterns and codes. (Recall also the requirement to initialize the ancillary data port control logic by clocking ACLK at least three (3) complete cycles before attempting to load the first register address). In the default power-on state, TPG Enable appears as bit 7 on the multi-function I/O port. The TPG is run by applying the appropriate frequency at the VCLK input for the format and rate selected and then setting the TPG Enable input on the multi-function I/O port, or by setting the TPG Enable bit in the TEST 0 register. Important: If the TPG Enable input of the I/O port is in its default mapping and is not being used to enable the TPG mode, attempting to enable TPG operation by setting bit 6 of the TEST 0 register will not cause the TPG to operate. This is because the low logic level at the I/O port input pulldown overrides the high level being written to the register. The result is the TPG does not run. The Pass/Fail bit in the TEST 0 control register indicates the test status. If no errors have been detected, this bit will be set to logic-1 approximately 2 field intervals after TPG En- able is set. If errors have been detected in the internal circuitry of the CLC030, Pass/Fail will remain reset to a www.national.com 13 |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |