| 数据搜索系统,热门电子元器件搜索 |
|
TLE4941 数据表(PDF) 11 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
TLE4941 数据表(HTML) 11 Page - Analog Devices |
|
11 / 16 page ![]() Detailed Description The MAX9621, an interface between two 2-wire Hall- effect sensors and a low-voltage microprocessor, supplies and monitors current through IN1 and IN2 to two Hall sensors. The MAX9621 complements Maxim’s existing family of Hall-effect sensor interfaces that includes the MAX9921. The MAX9621 provides two independent channels with two outputs for each channel, a digital output, and an analog output. The digital outputs (DOUT1 and DOUT2) are open-drain and indicate a logic level that corresponds to the Hall sensor status. DOUT1 or DOUT2 outputs high when the current out of IN1 or IN2, respectively, exceeds the high-input current threshold. DOUT1 or DOUT2 outputs low when the current flowing out of IN1 or IN2, respectively, is lower than the low-input current threshold. DOUT1 and DOUT2 provide a time domain output filter for robust noise immunity. See Figure 2. The analog outputs (AOUT1 and AOUT2) mirror the cur- rent flowing out to the corresponding inputs IN1 and IN2 with a nominal gain of 0.05mA/mA. Hall Sensor Protection from Supply Transients The MAX9621 protects the hall sensors from supply transients by shutting off current at IN1 and IN2 when the BAT voltage is 18V. The digital outputs go low and analog outputs have zero output current. When VBAT returns to the proper operating range, both inputs restart following a blanking cycle. PIN NAME FUNCTION 6 DOUT2 Open-Drain Output. Signal translated from Hall sensor 2. DOUT2 is high when the current flowing out of IN2 exceeds the input current threshold high, and is low when less than the input current threshold low. See Table 1 for output response to operating conditions. 7 AOUT2 Analog Current Output. Mirrors the current to the corresponding Hall sensor at IN2. When IN2 has been shut down due to a short to GND a current of zero is supplied to AOUT2. See Table 1 for output response to operating conditions. To obtain a voltage output, connect a resistor from AOUT_ to ground. 8 DOUT1 Open-Drain Output. Signal translated from Hall sensor 1. DOUT1 is high when the current flowing out of IN1 exceeds the input current threshold high, and is low when less than the input current threshold low. See Table 1 for output response to operating conditions. 9 AOUT1 Analog Current Output. Mirrors the current to the corresponding Hall sensor at IN1. When IN1 has been shut down due to a short to GND a current of zero is supplied to AOUT1. See Table 1 for output response to operating conditions. To obtain a voltage output, connect a resistor from AOUT_ to ground. 10 SLEEP Sleep Mode Input. The part is placed in sleep mode when the SLEEP input is low for more than 40µs. If the SLEEP input is low for less than 20µs and then goes high, the part restarts any Hall input that has been shut off due to a detected short to GND. Any Hall input that is operational is not affected when SLEEP is cycled low for less than 20µs. There is an internal 100kΩ pulldown resistance to GND. MAX9621 Dual, 2-Wire Hall-Effect Sensor Interface with Analog and Digital Outputs www.maximintegrated.com Maxim Integrated │ 11 Pin Description (continued) |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |