| 数据搜索系统,热门电子元器件搜索 |
|
TLE4941 数据表(PDF) 12 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
TLE4941 数据表(HTML) 12 Page - Analog Devices |
|
12 / 16 page ![]() Hall Input Short-to-Battery Condition The MAX9621 interprets a short to battery when the volt- age at IN1 or IN2 is higher than VBAT - 100mV. The digital outputs go low and the analog outputs are set to zero output current. If IN1 or IN2 is more than 1V above VBAT, it back-drives current into BAT. The MAX9621 restarts the Hall inputs when the Hall input is loaded again. Hall Input Short to Ground The Hall input short-to-ground fault is effectively a latched condition if the input remains loaded by the Hall switch. The current required to power the Hall switch is shut off and only a 50μA pullup current remains. The Hall input can be manually reenergized or it can be reenergized by the μP. A 10μs to 20μs negative pulse at SLEEP restarts with a blanking cycle any Hall input that has been shut down due to the short-to-ground condition. During startup or restart, it is possible for a Hall input to charge up an external capacitance of 0.02μF without tripping into a short-to-ground latched state. During the short-to-ground fault, DOUT1 and DOUT2 are high impedance (pulled high by the pullup resistors), while AOUT1 and AOUT2 are set to zero-output current. Manual Method for Reenergizing Hall Sensor and Means for Diagnosing an Intermittent Hall Sensor Connection Figure 3 shows the behavior of the MAX9621 when a Hall input is open. Figure 4 shows the behavior of the MAX9621 when the open input is reconnected to a Hall sensor. Figures 3 and 4 demonstrate how a short-to- ground Hall input can be reset. Resetting a short-to- ground Hall input involves three steps: 1) Relieve the short to ground at the Hall sensor. 2) Disconnect the Hall input from the Hall sensor (open- input fault condition). 3) Reconnect the Hall input to the Hall sensor. The MAX9621 restarts the Hall input with a blanking cycle. If the Hall input is disconnected from the Hall sen- sor for 10ms, it allows the Hall input to be pulled up by the 50µA pullup current to register the open-input fault condition. Reconnecting the Hall input to the Hall sensor restarts the Hall input with a blanking cycle. This provides a manual means of reenergizing a Hall input without hav- ing to resort to the µP to restart it. This also demonstrates the behavior of an intermittent connection to a Hall sensor. Figure 3. Hall Input Ramps to Open-Circuit Fault When a Short to Ground Is Relieved Table 1. AOUT_/DOUT_ Truth Table *If IN_ is already shorted to BAT or open during power-up, DOUT_ goes to high-Z until IN_ is loaded. CONDITION AOUT_ DOUT_ IN_ Short to GND 0 High-Z IN_ Short to BAT or IN_ Open 0 Low* SLEEP Low 0 High-Z VBAT > 18V 0 Low* 14V VIN_ VBAT - 25mV HALL INPUT OPEN-CIRCUIT FAULT 5mV/ms IIN_ 50µA 0V 0A TIME TIME HALL INPUT SHORT-TO- GROUND FAULT HALL INPUT DISCONNECTED FROM SENSOR MAX9621 Dual, 2-Wire Hall-Effect Sensor Interface with Analog and Digital Outputs www.maximintegrated.com Maxim Integrated │ 12 |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |