| 数据搜索系统,热门电子元器件搜索 |
|
M29W800AT 数据表(PDF) 12 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
M29W800AT 数据表(HTML) 12 Page - STMicroelectronics |
|
12 / 33 page ![]() M29W800AT, M29W800AB 12/33 During the second cycle the Coded cycles consist of writing the data 55h at address 555h in the Byte- wide configuration and at address 2AAh in the Word-wide configuration. In the Byte-wide config- uration the address lines A–1 to A10 are valid, in Word-wide A0 to A11 are valid, other address lines are ’don’t care’. The Coded cycles happen on first and second cycles of the command write or on the fourth and fifth cycles. Instructions See Table 9. Read/Reset (RD) Instruction. The Read/Reset instruction consists of one write cycle giving the command F0h. It can be optionally preceded by the two Coded cycles. Subsequent read opera- tions will read the memory array addressed and output the data read. A wait state of 10 µs is nec- essary after Read/Reset prior to any valid read if the memory was in an Erase mode when the RD instruction is given. The Read/Reset command is not accepted during Erase and erase Suspend. Auto Select (AS) Instruction. This instruction uses the two Coded cycles followed by one write cycle giving the command 90h to address AAAh in the Byte-wide configuration or address 555h in the Word-wide configuration for command set-up. A subsequent read will output the manufacturer code and the device code or the block protection status depending on the levels of A0 and A1. The manufacturer code, 20h, is output when the ad- dresses lines A0 and A1 are Low, the device code, EEh for Top Boot, EFh for Bottom Boot is output when A0 is High with A1 Low. The AS instruction also allows access to the block protection status. After giving the AS instruction, A0 is set to VIL with A1 at VIH, while A12-A18 de- fine the address of the block to be verified. A read in these conditions will output a 01h if the block is protected and a 00h if the block is not protected. Program (PG) Instruction. This instruction uses four write cycles. Both for Byte-wide configuration and for Word-wide configuration. The Program command A0h is written to address AAAh in the Byte-wide configuration or to address 555h in the Word-wide configuration on the third cycle after two Coded cycles. A fourth write operation latches the Address on the falling edge of W or E and the Data to be written on the rising edge and starts the P/E.C. Read operations output the Status Register bits after the programming has started. Memory programming is made only by writing ’0’ in place of ’1’. Status bits DQ6 and DQ7 determine if pro- gramming is on-going and DQ5 allows verification of any possible error. Programming at an address not in blocks being erased is also possible during erase suspend. In this case, DQ2 will toggle at the address being programmed. Table 11. Polling and Toggle Bits Note: 1. Toggle if the address is within a block being erased. ’1’ if the address is within a block not being erased. Mode DQ7 DQ6 DQ2 Program DQ7 Toggle 1 Erase 0 Toggle Note 1 Erase Suspend Read (in Erase Suspend block) 1 1 Toggle Erase Suspend Read (outside Erase Suspend block) DQ7 DQ6 DQ2 Erase Suspend Program DQ7 Toggle N/A Toggle Bit (DQ2). This toggle bit, together with DQ6, can be used to determine the device status during the Erase operations. It can also be used to identify the block being erased. During Erase or Erase Suspend a read from a block being erased will cause DQ2 to toggle. A read from a block not being erased will set DQ2 to ’1’ during erase and to DQ2 during Erase Suspend. During Chip Erase a read operation will cause DQ2 to toggle as all blocks are being erased. DQ2 will be set to ’1’ dur- ing program operation and when erase is com- plete. After erase completion and if the error bit DQ5 is set to ’1’, DQ2 will toggle if the faulty block is addressed. Error Bit (DQ5). This bit is set to ’1’ by the P/E.C. when there is a failure of programming, block erase, or chip erase that results in invalid data in the memory block. In case of an error in block erase or program, the block in which the error oc- curred or to which the programmed data belongs, must be discarded. The DQ5 failure condition will also appear if a user tries to program a ’1’ to a lo- cation that is previously programmed to ’0’. Other Blocks may still be used. The error bit resets after a Read/Reset (RD) instruction. In case of success of Program or Erase, the error bit will be set to ’0’. Erase Timer Bit (DQ3). This bit is set to ’0’ by the P/E.C. when the last block Erase command has been entered to the Command Interface and it is awaiting the Erase start. When the erase timeout period is finished, after 50 µsto 90µs, DQ3 returns to ’1’. Coded Cycles The two Coded cycles unlock the Command Inter- face. They are followed by an input command or a confirmation command. The Coded cycles consist of writing the data AAh at address AAAh in the Byte-wide configuration and at address 555h in the Word-wide configuration during the first cycle. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |