27 / 36 page ![]() 27/36 M50LPW040 Figure 14. Program Flowchart and Pseudo Code Note: 1. A Status check of b1 (Protected Block), b3 (VPP invalid) and b4 (Program Error) can be made after each Program operation by following the correct command sequence. 2. If an error is found, the Status Register must be cleared before further Program/Erase Controller operations. Write 40h or 10h AI04433 Start Write Address & Data Read Status Register YES NO b7 = 1 YES NO b3 = 0 NO b4 = 0 VPP Invalid Error (1, 2) Program Error (1, 2) Program command: – write 40h or 10h – write Address & Data (memory enters read status state after the Program command) do: –read Status Register if Program/Erase Suspend command given execute suspend program loop while b7 = 1 If b3 = 1, VPP invalid error: – error handler If b4 = 1, Program error: – error handler YES End YES NO b1 = 0 Program to Protected Block Error (1, 2) If b1 = 1, Program to protected block error: – error handler Suspend Suspend Loop NO YES LPC Interface Only |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|