| 数据搜索系统,热门电子元器件搜索 |
|
C11 数据表(PDF) 28 Page - ams-OSRAM AG |
|
|
|||||||||||||||||||||||||||||
C11 数据表(HTML) 28 Page - ams-OSRAM AG |
|
28 / 72 page ![]() AS3688 austriami crosyst ems Datasheet, Confidential www.austriamicrosystems.com (ptr,tje) Revision 1.1.1 / 20060707 26 - 70 curr12 control Addr: 01h This register select the mode of the current sinkscontrols High voltage current sink current. Bit Bit Name Default Access Description 1:0 curr1_mode 0 R/W Select the mode of the current sink curr1 00b = off 01b = on 10b = PWM controlled 11b = LED pattern controlled; do not use softdim_pattern=1 3:2 curr2_mode 0 R/W Select the mode of the current sink curr2 00b = off 01b = on 10b = PWM controlled 11b = LED pattern controlled; do not use softdim_pattern=1 DCDC Control 2 Addr: 22h This register controls the Step Up DC/DC Converter and low-voltage current sinks CURR3x. Bit Bit Name Default Access Description 0 step_up_res 0 R/W Gain selection for Step Up DC/DC Converter. 0 = Select 0 if Step Up DC/DC Converter is used with current feedback (CURR1, CURR2) or if DCDC_FB is used with current feedback only – only R1, C1 connected 1 = Select 1 if DCDC_FB is used with external resistor divider (2 resistors). 1 skip_fast 0 R/W Step Up DC/DC Converter output voltage at low loads, when pulse skipping is active. 0 = Accurate output voltage, more ripple. 1 = Elevated output voltage, less ripple. 2 stepup_prot 1 R/W Step Up DC/DC Converter protection. 0 = No overvoltage protection. 1 = Overvoltage protection on pin DCDC_FB enabled voltage limitation =1.25V on DCDC_FB 3 stepup_lowcur 1 R/W Step Up DC/DC Converter coil current limit. 0 = .Normal current limit 1 = Current limit reduced by approx. 33% 4 curr1_prot_on 0 R/W 0 = No overvoltage protection 1 = Pull down current on CURR1 switched on, if voltage on CURR1 exceeds 13.75V, and step_up_on=1 5 curr2_prot_on 0 R/W 0 = No overvoltage protection 1 = Pull down current on CURR2 switched on, if voltage exceeds on CURR2 13.75V, and step_up_on=1 7 step_up_fb_auto 0 R/W 0 = step_up_fb select the feedback of the DCDC converter 1 = The feedback is automatically chosen within the current sinks CURR1and CURR2 (never DCDC_FB). Only those are used for this selection, which are enabled (currX_mode must not be 00) and not connected to the charge pump (currX_on_cp must be 0). 7.4.2 High Current Sinks CURR30, CURR31, CURR32, CURR33 These current sinks have a preview and strobe setting. The preview and strobe can be controlled by software (register bit) or GPIO2 can be programmed to enter preview mode (polarity programmable) and GPI can be programmed to enter strobe mode (polarity programmable). |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |