21 / 72 page ![]() AS3688 austriami crosyst ems Datasheet, Confidential www.austriamicrosystems.com (ptr,tje) Revision 1.1.1 / 20060707 19 - 70 Table 10 – Charge Pump Characteristics Symbol Parameter Min Typ Max Unit Note ICPOUT_Pulsed Output Current Pulsed 0.0 900 mA 300ms pulse width, 10% duty cycle max. ICPOUT Output Current Continuous 0.0 400 mA VCPOUTmax Output Voltage 5.6 V Internally limited, Including output ripple η Efficiency 55 90 % Including current sink loss; ICPOUT < 400mA. ICP1_1.5 8.4 13 1:1.5 Mode ICP1_2 Power Consumption without Load fclk = 1 MHz 9.5 18 mA 1:2 Mode Rcp1_1 0.4 1.0 1:1 Mode; VBAT >= 3.5V Rcp1_1.5 1.4 2.0 1:1.5 Mode; VBAT >= 3.3V ; TJUNCTION<85°C Rcp1_2 Effective Charge Pump Output Resistance (Open Loop, fclk = 1MHz) 1.8 2.5 1:1.2 Mode; VBAT >= 3.1V fclk Accuracy Accuracy of Clock Frequency -10 10 % currlv_switch RGB1:RGB3 and CURR41:CURR42 minumum voltage 0.2 V currhv_switch CURR1, CURR2 minumum voltage 0.45 V CURR30:CURR33 minumum voltage 0-160mA range 0.2 V curr3x_switch CURR30:CURR33 minumum voltage >160mA range 0.4 V If the voltage drops below this threshold, the charge pump will use the next available mode (1:1 -> 1:1.5 or 1:1.5 -> 1:2) tdeb CP automatic up- switching debounce time 240 µsec 7.3.1 Charge Pump Mode Switching If automatic mode switching is enabled (cp_mode_switching = 00 or cp_mode_switching = 01) the charge pump monitors the current sinks, which are connected via a led to the output CP_OUT. To identify these current sources (sinks), the registers cp_mode_switch1 and cp_mode_switch2 (register bits curr30_on_cp … curr33_on_cp, rgb1_on_cp … rgb3_on_cp, curr1_on_cp, curr2_on_cp, curr41_on_cp … curr43_on_cp) should be setup before starting the charge pump (cp _on = 1). If any of the voltage on these current sources drops below the threshold (currlv_switch, currhv_switch, curr3x_switch), the next higher mode is selected after the debounce time. To avoid switching into 1:2 mode (battery current = 2 times output current), set cp_mode_switching = 10. If the currX_on_cp=0 and the according current sink is connected to the chargepump, the current sink will be functional, but there is no up switching of the chargepump, if the voltage compliance is too low for the current sink to supply the specified current. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |