| 数据搜索系统,热门电子元器件搜索 |
|
STMPE821 数据表(PDF) 8 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
STMPE821 数据表(HTML) 8 Page - STMicroelectronics |
|
8 / 55 page ![]() Capacitive compensation STMPE821 8/55 ETC WAIT register state a period of time of which, all TOUCH inputs must remain "NO TOUCH" for the next calibration to be carried out. CAL INTERVAL states the period of time between successive calibrations when there are prolonged NO TOUCH condition. 2.1.1 Noise filtering When the STMPE821 is operating in the vicinity of highly emissive circuits (DC-DC converter, PWM controller/drive etc), the sensor inputs will be affected by high-frequency noise. In this situation, the time-integrating function could be used to distinguish between real touch, or emission-related false touch. The INTEGRATION TIME and STRENGTH THRES registers are used to configure the time- integrating function of STMPE821. 2.1.2 Data filtering The output from the calibration unit is an instantaneous "TOUCH" or "NO TOUCH" status. This output is directed to the filtering stage where the TOUCH is integrated across a programmable period of time. The output of the integration stage would be a "STRENGTH" (in STRENGTH register) that indicates the number of times a "TOUCH" is seen, across the integration period. The "STRENGTH" is then compared with the value in "STRENGTH THRESHOLD" register. If STRENGTH exceeds the STRENGTH THRESHOLD, this is considered a final, filtered TOUCH status. In data filtering stage, 3 modes of operation is supported: Mode 1: Only the “touch” channel with highest STRENGTH is taken Mode 2: All the “touch” channels with STRENGTH > STRENGTH THRESHOLD is taken Mode 3: The 2 “touch” channel with the highest STRENGTH is taken These modes are selected using the FEATURE SELECTOR register. The final, filtered data is accessible through the Touch Byte register. Table 3. Calibration action under different scenarios Scenario Touch sensing and calibration action IMP>CALIBRATED IMP + TVR Touch sensing and calibration action No touch, no calibration IMP<CALIBRATED IMP + TVR IMP>CALIBRATED IMP + EVR No touch, no calibration IMP<CALIBRATED IMP + TVR IMP<CALIBRATED IMP + EVR No touch, new CALIBRATED IMP = previous IMP>CALIBRATED IMP CALIBRATED IMP + change in IMP IMP<CALIBRATED IMP No touch, new CALIBRATED IMP = new IMP |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |