75 / 190 page ![]() 75/190 ST90158 - RESET AND CLOCK CONTROL UNIT (RCCU) CLOCK CONTROL REGISTERS (Cont’d) CLOCK FLAG REGISTER (CLK_FLAG) R242 -Read/Write Register Page: 55 Reset Value: 0100 10x0 after a Watchdog Reset Reset Value: 0010 10x0 after a Software Reset Reset Value: 0000 10x0 after a Power-On Reset WARNING: If this register is accessed with a logi- cal instruction, such as AND or OR, some bits may not be set as expected. WARNING: If you select the CK_AF as system clock and turn off the oscillator (bits R240.2 and R242.4 at 1), and then switch back to the XT clock by resetting the R240.2 bit, you must wait for the oscillator to restart correctly (12ms). Bit 7 = EX_STP: External Stop flag This bit is set by hardware and cleared by soft- ware. 0: No External Stop condition occurred 1: External Stop condition occurred Bit 6 = WDGRES: Watchdog reset flag. This bit is read only. 0: No Watchdog reset occurred 1: Watchdog reset occurred Bit 5 = SOFTRES: Software Reset Flag. This bit is read only. 0: No software reset occurred 1: Software reset occurred (HALT instruction) Bit 4 = XTSTOP: External Stop Enable 0: External stop disabled 1: The Xtal oscillator will be stopped as soon as the CK_AF clock is present and selected, whether this is done explicitly by the user pro- gram, or as a result of WFI, if WFI_CKSEL has previously been set to select the CK_AF clock during WFI. WARNING: When the program writes ‘1’ to the XTSTOP bit, it will still be read as 0 and is only set when the CK_AF clock is running (CKAF_ST=1). Take care, as any operation such as a subsequent AND with ‘ 1’ or an OR with ‘ 0’ to the XTSTOP bit will reset it and the oscillator will not be stopped even if CKAF_ST is subsequently set. Bit 3 = XT_DIV16: CLOCK/16 Selection This bit is set and cleared by software. An interrupt is generated when the bit is toggled. 0: CLOCK2/16 is selected and the PLL is off 1: The input is CLOCK2 (or the PLL output de- pending on the value of CSU_CKSEL) WARNING: After this bit is modified from 0 to 1, take care that the PLL lock-in time has elapsed be- fore setting the CSU_CKSEL bit. Bit 2 = CKAF_ST: (Read Only) If set, indicates that the alternate function clock has been selected. If no clock signal is present on the CK_AF pin, the selection will not occur. If re- set, the PLL clock, CLOCK2 or CLOCK2/16 is se- lected (depending on bit 0). Bit 0 = CSU_CKSEL: CSU Clock Select This bit is set and cleared by software. It is also cleared by hardware when: – bits DX[2:0] (PLLCONF) are set to 111; – the quartz is stopped (by hardware or software); – WFI is executed while the LPOWFI bit is set; – the XT_DIV16 bit (CLK_FLAG) is forced to ’0’. This prevents the PLL, when not yet locked, from providing an irregular clock. Furthermore, a ‘0’ stored in this bit speeds up the PLL’s locking. 0: CLOCK2 provides the system clock 1: The PLL Multiplier provides the system clock. NOTE: Setting the CKAF_SEL bit overrides any other clock selection. Resetting the XT_DIV16 bit 70 EX_ STP WDGRE S SOF- TRES XT- STOP XT_ DIV16 CKAF_ ST - CSU_ CK- SEL 9 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |