39 / 52 page ![]() ADATE304 Rev. 0 | Page 39 of 52 DETAILS OF REGISTERS Table 21. PE/PMU Enable (ADDR[4:0] = 0x0C) Bit Name Description DATA[2] PMU enable 0 = disable PMU force output and clamps, place PMU in MV mode 1 = enable PMU force output When set to 0, the PMU state bits are ignored, except for the PMU sense path (DATA[7]) DATA[1] Force VT 0 = normal driver operation 1 = force driver to VT See Table 29 for complete functionality of this bit DATA[0] PE disable 0 = enable driver functions 1 = disable driver (low leakage) See Table 29 for complete functionality of this bit Table 22. Channel State (ADDR[4:0] = 0x0D) Bit Name Description DATA[2] HV mode select 0 = HV driver in low impedance. 1 = enable HV driver. This bit affects Channel 0 only. Ensure that the Channel 0 bit in SPI write is active. Channel 1 bit in SPI write is don’t care. DATA[1] Load enable 0 = disable load. 1 = enable load. See Table 29 for complete functionality of this bit. DATA[0] Driver high-Z or VT 0 = enable Driver high-Z function. 1 = enable Driver VTERM function. See Table 29 for complete functionality of this bit. Table 23. PMU State (ADDR[4:0] = 0x0E)1, 2 Bit Name Description DATA[9:8] PMU input selection 00 = VDUTGND (calibrated for 0.0 V voltage reference) 01 = 2.5 V + VDUTGND (calibrated for 0.0 A current reference) 1X = PMUDAC DATA[7] PMU sense path 0 = internal sense 1 = external sense DATA[6] Reserved DATA[5] PMU clamp enable 0 = disable clamps 1 = enable clamps DATA[4] PMU measure voltage or current 0 = measure voltage mode 1 = measure current mode DATA[3] PMU force voltage or current 0 = force voltage mode 1 = force current mode DATA[2:0] PMU range 0XX = 2 μA range 100 = 20 μA range 101 = 200 μA range 110 = 2 mA range 111 = 32 mA range 1 Note that when ADDR[4:0] = 0x0C, the PMU enable bit (DATA[2]) = 0, PMU force outputs and clamps are disabled, and the PMU is placed into measure voltage mode. PMU State DATA[9:8] and DATA[6:0] are ignored, and only the DATA[7] PMU sense path is valid. 2 X means don’t care. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |