| 数据搜索系统,热门电子元器件搜索 |
|
ADATE304BBCZ 数据表(PDF) 13 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADATE304BBCZ 数据表(HTML) 13 Page - Analog Devices |
|
13 / 52 page ![]() ADATE304 Rev. 0 | Page 13 of 52 Parameter Min Typ Max Unit Test Level Test Conditions/Comments FORCE CURRENT (FI) VDUTx externally forced to 0.0V, unless otherwise specified, ideal force current transfer function: IFORCE = (PMUDAC − 2.5) × (FSR/5) Force Current, DUTx Pin Voltage Range for All Ranges −1.25 +6.75 V D Force Current Uncalibrated Accuracy Range A −5.0 ±0.5 +5.0 mA P PMU enabled, FIMI, Range A, PE disabled, error at calibration points of −25 mA and +25 mA Range B −400 ±40 +400 μA P PMU enabled, FIMI, Range B, PE disabled, error at calibration points of −1.6 mA and 1.6 mA Range C −40 ±4 +40 μA P PMU enabled, FIMI, Range C, PE disabled, error at calibration points of ±80% FS Range D −4 ±0.4 +4 μA P PMU enabled, FIMI, Range D, PE disabled, error at calibration points of ±80% FS Range E −400 ±75 +400 nA P PMU enabled, FIMI, Range E, PE disabled, error at calibration points of ±80% FS Force Current Offset Tempco Range A ±1 μA/°C CT Measured at calibration points Range B ±80 nA/°C CT Measured at calibration points Range C to Range E ±4 nA/°C CT Measured at calibration points Forced Current Gain Error, Nominal Gain = 1 −20 ±4 +20 % P PMU enabled, FIMI, PE disabled, gain error from calibration points of ±80% FS Forced Current Gain Tempco Measured at calibration points Range A −500 ppm/°C CT Range B to Range E ±75 ppm/°C CT Force Current INL Range A −0.3 ±0.05 +0.3 %FSR P PMU enabled, FIMI, Range A, PE disabled, after two-point gain/offset calibration; measured over FSR output of −32 mA to +32 mA Range B to Range E −0.2 ±0.015 +0.2 %FSR P PMU enabled, FIMI, PE disabled, after two-point gain/offset calibration; measured over FSR output Force Current Compliance vs. Voltage Load PMU enabled, FIMV, PE disabled; force positive full-scale current driving −1.5 V and +6.0 V, measure ∆I @ DUTx pin; force negative full-scale current driving −1.25 V and +6.75 V, measure ∆I @ DUTx pin Range A to Range D −0.6 ±0.06 +0.6 %FSR P Range E −1.0 ±0.1 +1.0 %FSR P MEASURE VOLTAGE Measure Voltage Range −1.5 +6.0 V D Measure Voltage Uncalibrated Accuracy −25 ±2.0 +25 mV P PMU enabled, FVMV, Range B, PE disabled, error at calibration points of 0 V and 5 V, error = (VMEASOUT01 − VDUTx) Measure Voltage Offset Tempco ±10 μV/°C CT Measured at calibration points Measure Voltage Gain Error −0.2 ±0.01 +0.2 % P PMU enabled, FVMV, Range B, PE disabled, gain error from calibration points of 0 V and 5 V Measure Voltage Gain Tempco 25 ppm/°C CT Measured at calibration points Measure Voltage INL −7 ±1 +7 mV P PMU enabled, FVMV, Range B, PE disabled, after two-point gain/offset calibration; measured over output range of −1.25 V to +6.75 V Rejection of Measure V vs. IDUTx −1.5 ±0.1 +1.5 mV P PMU enabled, FVMV, Range D, PE disabled, force 0 V into load of −10 μA and +10 μA; measure ∆V reported at MEASOUT01 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |