| 数据搜索系统,热门电子元器件搜索 |
|
PCA2000U/AB 数据表(PDF) 7 Page - NXP Semiconductors |
|
|
|||||||||||||||||||||||||||||
PCA2000U/AB 数据表(HTML) 7 Page - NXP Semiconductors |
|
7 / 28 page ![]() PCA2000_2001_5 © NXP B.V. 2008. All rights reserved. Product data sheet Rev. 05 — 11 November 2008 7 of 28 NXP Semiconductors PCA2000; PCA2001 32 kHz watch circuit with programmable adaptive motor pulse The condition for a successful motor step is a positive step detection pulse (current in the same direction as in the driving phase) followed by a negative detection pulse within a given time limit. This time limit can be programmed between 3.9 ms and 10.7 ms (in steps of 0.98 ms) in order to ensure a safe and correct step detection under all conditions (for instance magnetic fields). The step detection phase stops after the last 31.25 ms, after the start of the motor driving pulse. 7.3 Time calibration The quartz crystal oscillator has an integrated capacitance of 5.2 pF, which is lower than the specified capacitance (CL) of 8.2 pF for the quartz crystal (see Table 10). Therefore, the oscillator frequency is typically 60 ppm higher than 32.768 kHz. This positive frequency offset is compensated by removing the appropriate number of 8192 Hz pulses in the divider chain (maximum 127 pulses), every 1 or 2 minutes. The time correction is given in Table 3. After measuring the effective oscillator frequency, the number of correction pulses must be calculated and stored together with the calibration period in the OTP memory (see Section 7.8). The oscillator frequency can be measured at pad RESET, where a square wave signal with the frequency of is provided. This frequency shows a jitter every minute or every two minutes, depending on the programmed calibration period, which originates from the time calibration. Details on how to measure the oscillator frequency and the programmed inhibition time are given in Section 7.11. 7.4 Reset At pad RESET an output signal with a frequency of is provided. Connecting pad RESET to VDD stops the motor drive and opens all four (P1, N1, P2 and N2) driver switches (see Figure 5). Connecting pad RESET to VSS activates the test mode. In this mode the motor output frequency is 32 Hz, which can be used to test the mechanical function of the watch. After releasing the pad RESET, the motor starts exactly one second later with the smallest duty cycle and with the opposite polarity to the last pulse before stopping. The debounce time for the RESET function is between 31 ms and 62 ms. Table 3. Time calibration Calibration period Correction per step (n = 1) Correction per step (n = 127) ppm seconds per day ppm seconds per day 1 minute 2.03 0.176 258 22.3 2 minutes 1.017 0.088 129 11.15 1 1024 ------------ f osc × 1 1024 ------------ f osc × 32 Hz = |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |