9 / 34 page ![]() NCP1237 http://onsemi.com 9 • Normal operation: As long as the feedback voltage is within the regulation range, the NCP1237 runs at a fixed frequency (with jittering) in current−mode control, where the peak current (sensed on the CS pin) is set by the voltage on the FB pin. A fixed ramp compensation is applied internally to prevent sub−harmonic oscillations from occurring. The VCC must be supplied by an external source (such as an auxiliary winding), as the startup current source cannot permanently supply the controller without overheating. • Light load operation: When the FB voltage decreases below VFB(fold), typically corresponding to a load of 20% (DCM design only) to 30% (CCM / DCM design) of the maximum load, the switching frequency starts to decrease down to fOSC(min). By lowering the switching losses, this feature helps to improve the efficiency in light load conditions. The frequency jittering is disabled in light load operation. • No load operation: When the FB voltage decreases below Vskip(in), typically corresponding to a load of 1% of the maximum load, the controller enters Skip mode. By completely stopping the switching while the feedback voltage is below Vskip(out), the losses are further reduced, allowing to minimize the power dissipation under extremely low load conditions. In order to avoid audible noise, the peak current is gradually increased during the tSSKIP duration while exiting the skip mode (Soft−Skip function). In case of abrupt load increase during Soft−Skip mode, the soft−skip portion is bypassed and the peak current needed for regulation is directly applied. VCC can be maintained between VCC(on) and VCC(min) by the DSS. • Overload: The NCP1237 features a timer−based dual−level overload detection, solely dependent on the feedback information: as soon as the internal peak current setpoint goes above the VCS(tran) threshold, a first internal timer starts to count, but the controller is still able to regulate up to VILIM. Once it reaches the VILIM clamp, the internal overload timer starts to count. When either timer times out, the controller stops and enters the protection mode, autorecovery for the B version (the controller initiates a new start−up after tautorec elapses), or latched for the A version (the latch is released if a brown−out event occurs or VCC is reset). • Brown−out: The NCP1237 features on its HV pin a true AC line monitoring circuitry which includes a minimum startup threshold, brown−out protection, and overvoltage protection. All of these circuits are autorecovery and operate independently of any ripple on the input voltage. They can even work with an unfiltered, rectified AC input. All thresholds are fixed, but they are designed to fit most of the standard ac−dc conversion applications. • Latch−off: When the Latch input is pulled up (typically by an overvoltage condition), or pulled low (typically by an overtemperature condition, using the provided current source with an NTC), the controller latches off. The latch is released when a brown−out condition occurs, or when VCC decreases below VCC(reset). |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |