13 / 34 page ![]() NCP1237 http://onsemi.com 13 When VHV crosses the VHV(start) threshold, the controller can start immediately. When it crosses VHV(stop), it triggers a timer of duration tHV: this ensures that the controller doesn’t stop in case of line cycle drop−out. Figure 7. AC Input Brown−out Timing Diagram time VHV time DRV VHV(start) Starts at next VCC(ON) VHV(stop) Brown-out HV t The same scheme is used for the Line OVP, except that this time the controller must not stop instantaneously when the input voltage goes above VHV(OV1). In order to be insensitive to spikes and voltage surges a blanking circuit is inserted after the output of the comparator, with a duration of tOV(blank). |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|