| 数据搜索系统,热门电子元器件搜索 |
|
ADT7320UCPZ-R2 数据表(PDF) 20 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADT7320UCPZ-R2 数据表(HTML) 20 Page - Analog Devices |
|
20 / 24 page ![]() ADT7320 Preliminary Technical Data Rev. PrA | Page 20 of 24 CONT READ C3 C2 C5 C4 DIN C7 C6 C1 C0 8-BIT DATA 5 6 7 8 9 10 1112 1314 15 16 SCLK 123 4 D6 D5 CS R/W REGISTER ADDR 0 0 0 D4 D3 D2 D1 D0 D7 DOUT 8-BIT COMMAND WORD Figure 18. Read from an 8-Bit Register C3 C2 C5 C4 DIN C7 C6 C1 D2 D1 D0 C0 16-BIT DATA 5 24 6 7 8 9 10 11 12 13 14 15 16 22 23 SCLK 12 3 4 D14 D13 17 CS R/W REGISTER ADDR 0 0 0 CONT READ D12 D11 D10 D9 D8 D7 D15 DOUT 8-BIT COMMAND BYTE Figure 19. Read from a 16-Bit Register READING DATA A read transaction begins when the master writes the command byte to the ADT7320 with the read/write bit set to 1. The master then supplies 8 or 16 clock pulses, depending on the addressed register, and the ADT7320 clocks out data from the addressed register on the DOUT line. Data is clocked out on the first falling edge of SCLK following the command byte. The read transaction finishes when the master takes CS high. The master must begin a new read transaction on the bus for every register read. Only one register is read per bus transaction. However, in continuous read mode, Command Byte C2 = 1 and the temperature value register can be read from continuously. The master sends 16 clock pulses on SCLK, and the temperature value is clocked out on DOUT. See Figure 18 and Figure 19. INTERFACING TO DSPs OR MICROCONTROLLERS The ADT7320 can be operated with CS used as a frame syn- chronization signal. This scheme is useful for DSP interfaces. In this case, the first bit (MSB) is effectively clocked out by CS because CS normally occurs after the falling edge of SCLK in DSPs. SCLK can continue to run between data transfers, provided that the timing numbers are obeyed. CS can be tied to ground and the serial interface can operate in a 3-wire mode. DIN, DOUT, and SCLK are used to communicate with the ADT7320 in this mode. For microcontroller interfaces, it is recommended that SCLK idle high between data transfers. SERIAL INTERFACE RESET The serial interface can be reset by writing a series of 1s on the DIN input. If a Logic 1 is written to the ADT7320 line for at least 32 serial clock cycles, the serial interface is reset. This ensures that the interface can be reset to a known state if the interface gets lost due to a software error or some glitch in the system. Reset returns the interface to the state in which it is expecting a write to the communications register. This operation resets the contents of all registers to their power-on values. Following a reset, the user should allow a period of 500 μs before addressing the serial interface. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |