4 / 32 page ![]() MCP2003/4 DS22230A-page 4 2010 Microchip Technology Inc. 1.3 Modes of Operation For an overview of all operational modes, refer to Table 1-1. 1.3.1 POWER-DOWN MODE In Power Down mode, the transmitter and VREN are both off. Only the receiver section and the wake-up circuits are operational. This is the lowest power mode. On bus activity (e.g. a BREAK character), CS going to a high level, or on a falling edge on WAKE, the device will immediately enter Ready mode. If CS is held high as the device transitions from Power Down to Ready mode, the device will transition to Operation mode as soon as internal voltages stabilize. 1.3.2 READY MODE Upon entering the Ready mode, VREN is enabled and the receiver detect circuit is powered up. The transmit- ter remains disabled and the device is ready to receive data but not to transmit. Upon VBB supply pin power-on, the device will remain in Ready mode as long as CS is low. If CS transitions high, the device will enter Operation mode. However, if the TXD pin is held low when CS goes high, the device will transition to Transmitter Off mode instead of Operation mode. 1.3.3 OPERATION MODE In this mode, all internal modules are operational. The MCP2003/4 will go into the Power Down mode on the falling edge of CS. The MCP2003/4 will enter Transmitter Off mode in the event of a Fault condition. These include: thermal overload, bus contention and TXD timer expiration. The MCP2004 device can also enter Transmitter Off mode if the FAULT/TXE pin is pulled low 1.3.4 TRANSMITTER OFF MODE Transmitter Off mode is reached whenever the transmitter is disabled either due to a Fault condition or pulling the nFAULT/TXE pin low on the MCP2004. The fault conditions include: thermal overload, bus contention or TXD timer expiration. The MCP2003/4 will go into Power Down mode on falling edge of CS, or return to Operation mode if all faults are resolved and the FAULT/TXE pin on the MCP2004 is high. FIGURE 1-2: OPERATIONAL MODES STATE DIAGRAM – MCP2003 Note: Bus activity is defined as LBUS dropping below VIL(LBUS) for longer than the Bus Activity Debounce time (tBDB). Operation Mode VREN ON RX ON TX ON Ready Mode VREN ON RX ON TX OFF TOFF Mode VREN ON RX ON TX OFF Sleep Mode VREN OFF RX OFF TX OFF VBB > 5.5V CS = 1 and TXD = 0 CS=0 CS = 1 and TXD = 1 CS=0 Falling edge on LIN or CS = 1 CS = 1 and TXD = 1 and No Fault Fault (Thermal or Timer) POR VREN OFF RX OFF TX OFF |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |