| 数据搜索系统,热门电子元器件搜索 |
|
CLP200M 数据表(PDF) 7 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
CLP200M 数据表(HTML) 7 Page - STMicroelectronics |
|
7 / 21 page ![]() Obsolete Product(s) - Obsolete Product(s) CLP200M 7/21 Fig. 7a and 7b : Switching-on current versus RSENSE. 0.01 0.1 1 10 10 100 1000 t (ms) Ipp (A) Fig. 9 : Operation limits and destruction zone of the CLP200M. CLP200M Rsense Rsense 1 FAILURE +12V 1k STATUS Fig. 8 : Failure Status circuit and diagnostic. 3 5 7 9 11 13 100 200 300 500 Rsense ( ) Ω ISWON (mA) -20°C 25°C 75°C 35 7 9 11 100 200 300 500 Rsense ( ) Ω Iswon @ 25°C (mA) Iswon min Iswon max Iswon min Iswon min negative negative positive positive The choice of the switching-on current is function of the RSENSE resistors. In normal operating condition, only the negative current of the signal is of interest. This current (typ- ically below -150 mA) should not activate the pro- tection device CLP200M. Therefore the level of activation is to be chosen just above this limit (typi- cally -200 mA). This level is adjusted through RSENSE. Figures 7a and 7b enable the designers to choose the right RSENSE value. EXAMPLE : The choice of RSENSE =4 Ω ensures a negative triggering of -220 mA min and -320 mA max. In this case, the positive triggering will be 180mA min and 280 mA max. 2.5 . Failure Status The CLP200M has an internal feature that allows the user to get a Failure Status (FS) indication. When the CLP200M is short-circuiting the line to GND, a signal can be managed through pin 1. This signal can be used to turn a LED on in order to pro- vide a surge indication. It may also be used with a logic circuitry to count the number of disturbances appearing on the lines. If a surge exceeding the maximum ratings of the CLP200M occurs on the line, the device will fail in a short-circuit state. The figure 9 shows two different curves : s The lower one indicates the maximum guaranted working limits of the CLP200M. s The upper curve shows the limit above which the CLP200M is completely destructed . In this case, the Fail Diagnostic pin is on. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |