| 数据搜索系统,热门电子元器件搜索 |
|
LTC4263 数据表(PDF) 20 Page - Linear Technology |
|
|
|||||||||||||||||||||||||||||
LTC4263 数据表(HTML) 20 Page - Linear Technology |
|
20 / 28 page ![]() LTC4274 20 4274fa APPLICATIONS INFORMATION current reaches the inrush current limit level (typically 450mA), at which point the GATE pin will be servoed to maintain the specified IINRUSH current. During this inrush period, a timer (tSTART) runs. When output charging is complete, the port current will fall and the GATE pin will be allowed to continue rising to fully enhance the MOSFET and minimize its on-resistance. The final VGS is nominally 13V. If the tSTART timer expires before the inrush period completes, the port will be turned back off and a tSTART fault reported. Current Limit Each LTC4274 port includes two current limiting thresholds (ICUT and ILIM), each with a corresponding timer (tCUT and tLIM). Setting the ICUT and ILIM thresholds depends on several factors: the class of the PD, the voltage of the main supply (VEE), the type of PSE (1 or 2), the sense resistor (0.5Ω or 0.25Ω), the SOA of the MOSFET, and whether or not the system is required to implement class enforcement. Per the IEEE spec, the LTC4274 will allow the port cur- rent to exceed ICUT for a limited period of time before removing power from the port, whereas it will actively control the MOSFET gate drive to keep the port current below ILIM. The port does not take any action to limit the current when only the ICUT threshold is exceeded, but does start the tCUT timer. The tLIM timer starts when the ILIM threshold is exceeded and current limit is active. If the current drops below the ICUT current threshold before its timer expires, the tCUT timer counts back down, but at 1/16 the rate that it counts up. This allows the current limit circuitry to tolerate intermittent overload signals with duty cycles below about 6%; longer duty cycle overloads will turn the port off. ICUT is typically set to a lower value than ILIM to allow the port to tolerate minor faults without current limiting. Per the IEEE specification, the LTC4274 will automatically set ILIM to 425mA (shown in bold in Table 5) during in- rush at port turn-on, and then switch to the programmed ILIM setting once inrush has completed. To maintain IEEE compliance, ILIM should kept at 425mA for all Type 1 PDs, and 850mA if a Type 2 PD is detected. ILIM is automatically reset to 425mA when a port turns off. Table 5. Example Current Limit Settings ILIM (mA) INTERNAL REGISTER SETTING (hex) RSENSE = 0.5Ω RSENSE = 0.25Ω 53 88 106 08 88 159 89 213 80 08 266 8A 319 09 89 372 8B 425 00 80 478 8E 531 92 8A 584 CB 638 10 90 744 D2 9A 850 40 C0 956 4A CA 1063 50 D0 1169 5A DA 1275 60 E0 1488 52 49 1700 40 1913 4A 2125 50 2338 5A 2550 60 2975 52 ILIM Foldback The LTC4274 features a two-stage foldback circuit that reduces the port current if the port voltage falls below the normal operating voltage. This keeps MOSFET power dissipation at safe levels for typical 802.3af MOSFETs, |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |