  ADP1614ACPZ-650-R7 Datasheet HTML 1Page - Analog Devices ADP1614ACPZ-650-R7 Datasheet HTML 2Page - Analog Devices ADP1614ACPZ-650-R7 Datasheet HTML 3Page - Analog Devices ADP1614ACPZ-650-R7 Datasheet HTML 4Page - Analog Devices ADP1614ACPZ-650-R7 Datasheet HTML 5Page - Analog Devices ADP1614ACPZ-650-R7 Datasheet HTML 6Page - Analog Devices ADP1614ACPZ-650-R7 Datasheet HTML 7Page - Analog Devices ADP1614ACPZ-650-R7 Datasheet HTML 8Page - Analog Devices ADP1614ACPZ-650-R7 Datasheet HTML 9Page - Analog Devices Next Button
Zoom Inzoom in Zoom Outzoom out
 5 / 16 page
background image
Data Sheet
ADP1614
Rev. 0 | Page 5 of 16
PIN CONFIGURATION AND FUNCTION DESCRIPTIONS
1
COMP
2
FB
3
EN
4
GND
5
GND
10 SS
9
CLRES
8
VIN
7
SW
6
SW
ADP1614
TOP VIEW
(Not to Scale)
NOTES
1. THE EXPOSED PAD IS NOT ELECTRICALLY
CONNECTED; CONNECT THIS PAD TO A GROUND
PLANE FOR BETTER HEAT DISTRIBUTION.
Figure 2. Pin Configuration
Table 4. Pin Function Descriptions
Pin No.
Mnemonic
Description
1
COMP
Compensation Input. Connect a series resistor-capacitor network from COMP to GND to compensate the regulator.
2
FB
Output Voltage Feedback Input. Connect a resistive voltage divider from the output voltage to FB to set the
regulator output voltage.
3
EN
Enable Input. Drive EN low to shut down the regulator; drive EN high to turn on the regulator.
4, 5
GND
Ground.
6, 7
SW
Switching Output. Connect the power inductor from the input voltage to SW and connect the external rectifier
from SW to the output voltage to complete the step-up converter.
8
VIN
Main Power Supply Input. VIN powers the ADP1614 internal circuitry. Connect VIN to the input source voltage.
Bypass VIN to GND with a 10 µF or greater capacitor as close to the ADP1614 as possible.
9
CLRES
Connect a resistor to GND to set the peak inductor current.
10
SS
Soft Start. A capacitor connected from SS to GND brings up the output slowly at power-up and reduces inrush
current.
11
EP
Exposed Die Attach Pad. The exposed pad is not electrically connected; connect this pad to a ground plane for
better heat distribution.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16


数据表 下载

Go To PDF Page


链接网址



ALLDATASHEET是否为您带来帮助?  [ DONATE ] 

关于 Alldatasheet   |   广告服务   |   联系我们   |   隐私政策   |   数据表链接    |   链接交换   |   制造商名单
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com