| 数据搜索系统,热门电子元器件搜索 |
|
MMA6525KW 数据表(PDF) 52 Page - Freescale Semiconductor, Inc |
|
|
|||||||||||||||||||||||||||||
MMA6525KW 数据表(HTML) 52 Page - Freescale Semiconductor, Inc |
|
52 / 56 page ![]() Sensor 52 Freescale Semiconductor, Inc. MMA65xx 4.5.5 Internal Error The following errors will result in an internal error, and set the IDE bit in the DEVSTAT register: • OTP CRC Failure • Writable Register CRC Failure • Self Test Error • Invalid internal logic states 4.5.5.1 CRC Error If the IDE bit is set in the DEVSTAT register due to one or more of the following errors, the device will respond to acceleration data requests with an “Internal Error Present” response until the IDE bit is cleared in the DEVSTAT register. • An OTP Shadow Register CRC failure as described in Section 3.2 • A Writable Register CRC failure as described in Section 3.2 • A clock monitor CRC failure as described in Section 3.4.2 The arming function will not be updated on Acceleration Data Request commands if a CRC Error is detected. The PCM output is not affected by the CRC error. If the CRC error is in the writable register array, and the ENDINIT bit in the DEVCFG register has been set, the error can only be cleared by a device reset. The IDE bit will not be cleared on a read of the DEVSTAT register. If the CRC error is in the OTP shadow register array, the error cannot be cleared. Register operations will be executed as specified in Section 4.4. 4.5.5.2 Self Test Error If the IDE bit is set in the DEVSTAT register due to a Self Test activation failure, the device will respond to acceleration data requests with a “Self Test Error” response until the IDE bit is cleared in the DEVSTAT register. The arming function will not be updated on Acceleration Data Request commands if a Self Test Error is detected. The PCM output is not affected by the Self Test Error. The IDE bit in the DEVSTAT register will remain set until a read of the DEVSTAT register occurs, even if the internal failure is removed. If the internal error is still present when the DEVSTAT register is read, the IDE bit will remain set. Register operations will be executed as specified in Section 4.4. 4.5.6 Offset Monitor Error If an offset monitor error is present as described in Section 3.8.5, the OFFSET_X or OFFSET_Y bit in the DEVSTAT register will be set. The device will respond to an acceleration request for the corresponding axis with an “Internal Error Present” response until the OFFSET_X or OFFSET_Y bit is cleared in the DEVSTAT register. The arming function will not be updated. Once the error condition is removed, the OFFSET_X or OFFSET_Y bit in the DEVSTAT register will remain set until a read of the DEVSTAT register occurs. The PCM output is not affected by the offset monitor over range condition. Register operations will be executed as specified in Section 4.4. 4.6 Initialization SPI Response The first data transmitted by the device following reset is the SPI Error response shown in Table 30. This ensures that an un- expected reset will always be detectable. The device will respond to all acceleration data requests with the “Invalid Acceleration Data Request” response until the DEVRES bit in the DEVSTAT register is cleared via a read of the DEVSTAT register. The arming function will not be updated on Acceleration Data Request commands until the DEVRES bit in the DEVSTAT register is cleared. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |