| 数据搜索系统,热门电子元器件搜索 |
|
TNETA1500 数据表(PDF) 9 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
TNETA1500 数据表(HTML) 9 Page - Texas Instruments |
|
9 / 10 page ![]() TNETA1500 155.52-MBIT/S SONET/SDH ATM RECEIVER/TRANSMITTER SDNS021D – MARCH 1994 – REVISED JANUARY 1998 9 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 receive operation (continued) After descrambling, the ATM cell is passed to the output buffer, which operates as a FIFO. The receive-cell interface consists of the output data (RD0–RD7), receive-clock input (RCKI), receive-read-enable input (RRE), receive-FIFO-empty output (RXFE), beginning-of-ATM-cell indicator (RXCELL), and loss-of-receive-data alarm (LOSRD). Data is sent out from the device on the rising edge of RCKI when RRE is low. The LOSRD alarm goes active when the output FIFO overflows. In this case, the last cell placed into the FIFO is overwritten. The output FIFO holds three complete ATM cells. Cumulative counts of receive B1, B2, and B3 errors are provided by registers accessible through the controller interface. These registers maintain running totals of B1, B2, and B3 block errors and coding violations. The block-error counters maintain a count of the number of frames that are received with B1, B2, and B3 errors. The coding-violation counters count the exact number of B1, B2, and B3 bit-interleaved parity (BIP) errors that occur. It is possible for a single frame to contain 8 B1, 24 B2, and 8 B3 BIP errors. When any of the block-error or coding-violation counters reach maximum count, a bit is set in the interrupt registers and an interrupt is generated. These counters are rollover counters that roll over to zero after the maximum count occurs and an interrupt is generated (see the controller-interface operation section for additional information). When the receive side enters an LOCA state, a path RDI may need to be sent out the transmit side through the outgoing G1 byte. A path-RDI alarm is declared when an LOCA state is persistent for an amount of time (also known as soak time) that has not yet been specified by any industry standards. To provide maximum flexibility with regard to this unspecified soak time, an 8-bit counter is provided through the controller interface that allows the user to program the amount of soak time for a path-RDI alarm in increments of 125 µs. This counter is preset (when a device reset occurs) to a value of 4 ms, which is the anticipated soak time for a path-RDI alarm. controller-interface operation The controller interface provides access to the internal memory locations that contain the control registers, interrupt registers, interrupt-mask registers, and the ID register. Table 3 shows a memory map of the locations of the various registers in the TNETA1500. Table 3. TNETA1500 Register-Memory Map ADDRESS (HEX VALUE) REGISTER ADDRESS (HEX VALUE) REGISTER 00 Interrupt register 1 0D B1 block-error counter 01 Interrupt register 2 0E Not implemented 02 Interrupt register 3 0F B2 block-error counter 03 ID register 10 Not implemented 04 Not implemented 11 B3 block-error counter 05 Control register 1 12 B1 coding-violation counter (LSB) 06 Control register 2 13 B1 coding-violation counter (MSB) 07 Interrupt-mask register 1 14 B2 coding-violation counter (LSB) 08 Interrupt-mask register 2 15 B2 coding-violation counter 09 Interrupt-mask register 3 16 B2 coding-violation counter (MSB) 0A Multierrored cell counter 17 B3 coding-violation counter (LSB) 0B Path-RDI soak counter 18 B3 coding-violation counter (MSB) 0C Not implemented >18 Not implemented |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |