| 数据搜索系统,热门电子元器件搜索 |
|
AD9807JS 数据表(PDF) 19 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
AD9807JS 数据表(HTML) 19 Page - Analog Devices |
|
19 / 24 page ![]() AD9807/AD9805 –19– REV. 0 To calibrate the AD9807/AD9805 for a particular scan, use the following sequence. SET DIGITAL GAIN RANGE YES NO SET PGA GAIN(S) (INPUT OFFSET = 0mV) SCAN DARK LINE COMPUTE PIXEL OFFSETS SET INPUT OFFSET SET ODD/EVEN OFFSET SET GAIN/OFFSET BUS SIZE SET EXTERNAL PIXEL OFFSET VECTORS SCAN WHITE LINE NO ADJUST PGA GAIN(S) ? COMPUTE PIXEL GAINS SET ANOTHER COLOR ? YES Figure 20. Calibration Power-On Initialization and Calibration Sequence When the AD9807/AD9805 is powered on, the following sequence should be used to initialize the part to a known state. The digital gain and offset buses are disabled until the calibra- tion sequence. The Bayer mode register must be written to and set to zero if this mode is not going to be used. WRITE TO CONFIGURATION REGISTER SET DIGITAL GAIN RANGE TO 000 SET GAIN/OFFSET BUS SIZE TO 000 SET COLOR POINTER OPTIONAL READBACK FROM REGISTERS WRITE TO PGA GAIN REGISTER SET TO GAIN OF ONE (0000) WRITE TO INPUT OFFSET REGISTER SET TO 0mV (11001100) WRITE TO CONFIGURATION 2 REGISTER SET CDS OR SHA OPERATION SET 3-CHANNEL OR 1-CHANNEL MODE SET ADC FULL-SCALE RANGE SET CLAMP MODE WRITE TO BAYER MODE REGISTER SET MODE ON OR OFF YES NO CHANGE POINTER SET ANOTHER COLOR ? Figure 19. Initialization |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |