13 / 14 page ![]() –13– PRELIMINARY TECHNICAL DATA REV. PrC. ADE7757 Table III. Maximum Output Frequency on CF SCF S1 S0 CF Max for AC Signals (Hz) 1 0 0 128 x F1, F2 = 22.4 0 0 0 64 x F1, F2 = 11.2 1 0 1 64 x F1, F2 = 22.4 0 0 1 32 x F1, F2 = 11.2 1 1 0 32 x F1, F2 = 22.4 0 1 0 16 x F1, F2 = 11.2 1 1 1 16 x F1, F2 = 22.4 0 1 1 2048 x F1, F2 = 2.867 kHz SELECTING A FREQUENCY FOR AN ENERGY METER APPLICATION As shown in Table I, the user can select one of four fre- quencies. This frequency selection determines the maxi- mum frequency on F1 and F2. These outputs are intended for driving an energy register (electromechanical or oth- ers). Since only four different output frequencies can be selected, the available frequency selection has been opti- mized for a meter constant of 100 imp/kWhr with a maxi- mum current of between 10 A and 120 A. Table IV shows the output frequency for several maximum currents (IMAX) with a line voltage of 220 V. In all cases the meter con- stant is 100 imp/kWhr. Table IV. F1 and F2 Frequency at 100 imp/kWhr I MAX F1 and F2 (Hz) 12.5 A 0.076 25.0 A 0.153 40.0 A 0.244 60.0 A 0.367 80.0 A 0.489 120.0 A 0.733 The F1–4 frequencies allow complete coverage of this range of output frequencies (F1, F2). When designing an energy meter the nominal design voltage on Channel V2 (voltage) should be set to half-scale to allow for calibration of the meter constant. The current channel should also be no more than half-scale when the meter sees maximum load. This will allow over cur- rent signals and signals with high crest factors to be accommo- dated. Table V shows the output frequency on F1 and F2 when both analog inputs are half-scale. The frequencies listed in Table V align very well with those listed in Table IV for maxi- mum load. Table V. F1 and F2 Frequency with Half-Scale AC Inputs Frequency on F1 and F2– S1 S0 F1–4 CH1 and CH2 Half-Scale AC Inputs 0 0 0.85 0.0438 Hz 0 1 1.7 0.0875 Hz 1 0 3.4 0.175 Hz 1 1 6.8 0.35 Hz When selecting a suitable F1–4 frequency for a meter de- sign, the frequency output at IMAX (maximum load) with a meter constant of 100 imp/kWhr should be compared with Column 4 of Table V. The closest frequency in Table V will determine the best choice of frequency (F1–4). For example, if a meter with a maximum current of 25 A is being designed, the output frequency on F1 and F2 with a meter constant of 100 imp/kWhr is 0.153 Hz at 25 A and 220 V (from Table IV). Looking at Table V, the closest frequency to 0.153 Hz in column four is 0.175 Hz. There- fore F3 (3.4 Hz—see Table I) is selected for this design. Frequency Outputs Figure 1 shows a timing diagram for the various frequency outputs. The outputs F1 and F2 are the low frequency outputs that can be used to directly drive a stepper motor or elec- tromechanical impulse counter. The F1 and F2 outputs provide two alternating low frequency pulses. The pulsewidth (t1) is set such that if F1 and F2 falls below 1100 ms (0.909 Hz) the pulsewidth of F1 and F2 is set to half of their period. The maximum output frequencies for F1 and F2 are shown in Table II. The high frequency CF output is intended to be used for communications and calibration purposes. CF produces a 180 ms-wide active high pulse (t4) at a frequency propor- tional to active power. The CF output frequencies are given in Table III. As in the case of F1 and F2, if the period of CF (t5) falls below 360 ms, the CF pulsewidth is set to half the period. For example, if the CF frequency is 20 Hz, the CF pulsewidth is 25 ms. NOTE: When the high frequency mode is selected, (i.e., SCF = 0, S1 = S0 = 1) the CF pulsewidth is fixed at 36 µs. Therefore t4 will always be 36 µs, regardless of output frequency on CF. NO LOAD THRESHOLD The ADE7757 also includes a “no load threshold” and “start- up current” feature that will eliminate any creep effects in the meter. The ADE7757 is designed to issue a minimum output frequency. Any load generating a frequency lower than this minimum frequency will not cause a pulse to be issued on F1, F2 or CF. The minimum output frequency is given as 0.0014% of the full-scale output frequency for each of the F1–4 frequency selections—see Table I. For example, an energy meter with a meter constant of 100 imp/kWhr on F1, F2 using F3 (3.4 Hz), the minimum output frequency at F1 or F2 would be 0.0014% of 3.4 Hz or 4.76 x 10 –5 Hz. This would be 3.05 x 10 –3 Hz at CF (64 x F1 Hz) when SCF = S0 = 1, S1 = 0. In this example the no load threshold would be equivalent to 1.7 W of load or a start- up current of 8 mA at 220 V. Comparing this value to the IEC1036 specification which states that the meter must start up with a load equal to or less than 0.4% Ib. For a 5A (Ib) meter 0.4% of Ib is equivalent to 20 mA. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |