21 / 40 page ![]() Data Sheet ADP5052 Rev. 0 | Page 21 of 40 FREQUENCY FOLDBACK The buck regulators in the ADP5052 include frequency fold- back to prevent output current runaway when a hard short occurs on the output. Frequency foldback is implemented as follows: • If the voltage at the FBx pin falls below half the target output voltage, the switching frequency is reduced by half. • If the voltage at the FBx pin falls again to below one-fourth the target output voltage, the switching frequency is reduced to half its current value, that is, to one-fourth of fSW. The reduced switching frequency allows more time for the inductor current to decrease but also increases the ripple cur- rent during peak current regulation. This results in a reduction in average current and prevents output current runaway. Pulse Skip Mode Under Maximum Duty Cycle Under maximum duty cycle conditions, frequency foldback maintains the output in regulation. If the maximum duty cycle is reached—for example, when the input voltage decreases—the PWM modulator skips every other PWM pulse, resulting in a switching frequency foldback of one-half. If the duty cycle increases further, the PWM modulator skips two of every three PWM pulses, resulting in a switching frequency foldback to one-third of the switching frequency. Frequency foldback increases the effective maximum duty cycle, thereby decreasing the dropout voltage between the input and output voltages. HICCUP PROTECTION The buck regulators in the ADP5052 include a hiccup mode for overcurrent protection (OCP). When the peak inductor current reaches the current-limit threshold, the high-side MOSFET turns off and the low-side MOSFET turns on until the next cycle. When hiccup mode is active, the overcurrent fault counter is incremented. If the overcurrent fault counter reaches 15 and overflows (indicating a short-circuit condition), both the high- side and low-side MOSFETs are turned off. The buck regulator remains in hiccup mode for a period equal to seven soft start cycles and then attempts to restart from soft start. If the short- circuit fault has cleared, the regulator resumes normal operation; otherwise, it reenters hiccup mode after the soft start. Hiccup protection is masked during the initial soft start cycle to enable startup of the buck regulator under heavy load conditions. Note that careful design and proper component selection are required to ensure that the buck regulator recovers from hiccup mode under heavy loads. Hiccup protection can be enabled or disabled for all four buck regulators by factory fuse. When hiccup protection is disabled, the frequency foldback feature is still avail- able for overcurrent protection. LATCH-OFF PROTECTION The buck regulators in the ADP5052 have an optional latch-off mode to protect the device from serious problems such as short- circuit and overvoltage conditions. Latch-off mode can be enabled by factory fuse. Short-Circuit Latch-Off Mode Short-circuit latch-off mode is enabled by factory fuse (on or off for all four buck regulators). When short-circuit latch-off mode is enabled and the protection circuit detects an overcurrent status after a soft start, the buck regulator enters hiccup mode and attempts to restart. If seven continuous restart attempts are made and the regulator remains in the fault condition, the regulator is shut down. This shutdown (latch-off) condition is cleared only by reenabling the channel or by resetting the channel power supply. Note that short-circuit latch-off mode does not work if hiccup protection is disabled. Figure 46 shows the short-circuit latch-off detection function. OUTPUT VOLTAGE TIME LATCH-OFF LATCH OFF THIS REGULATOR SHORT CIRCUIT DETECTED BY COUNTER OVERFLOW PWRGD 7 × tSS SCP LATCH-OFF FUNCTION ENABLED AFTER 7 RESTART ATTEMPTS ATTEMPT TO RESTART Figure 46. Short-Circuit Latch-Off Detection Overvoltage Latch-Off Mode Overvoltage latch-off mode is enabled by factory fuse (on or off for all four buck regulators). The overvoltage latch-off threshold is 124% of the nominal output voltage level. When the output voltage exceeds this threshold, the protection circuit detects the overvoltage status and the regulator shuts down. This shutdown (latch-off) condition is cleared only by reenabling the channel or by resetting the channel power supply. Figure 47 shows the overvoltage latch-off detection function. OUTPUT VOLTAGE TIME LATCH OFF THIS REGULATOR LATCH-OFF 124% NOMINAL OUTPUT 100% NOMINAL OUTPUT CHx ON Figure 47. Overvoltage Latch-Off Detection |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |