16 / 37 page ![]() ADIS16000/ADIS16229 Preliminary Technical Data Rev. PrA | Page 16 of 37 SENSOR NODE RECORDING MODE/SIGNAL PROCESSING The ADIS16229 provides a complete sensing system for recording and monitoring vibration data. Figure 15 provides a simplified block diagram for the signal processing associated with spectral record acquisition on both axes (x and y). User registers provide controls for data type (time or frequency), trigger mode (manual or automatic), collection mode (real time or capture), sample rates/filtering, windowing, FFT averaging, spectral alarms, and I/O management. RECORDING MODE The recording mode selection establishes the data type (time or frequency domain), trigger type (manual or automatic), and data collection (captured or real time). The REC_CTRL1[1:0] bits (see Table 27) provide four operating modes: manual FFT, automatic FFT, manual time capture, and real time. After setting REC_CTRL1, the manual FFT, automatic FFT, and manual time capture modes require a start command to start acquiring a spectral or time domain record. All of these modes automatically trigger when the sensor receives the configuration packet from the gateway. Set GLOB_CMD[11] = 1 to halt the operation and wait for further instructions from the ADIS16000.. Table 27. REC_CTRL1 Page 1-6, Low Byte Address = 0x1A, Read/Write Bits Description (Default = 0x1100) [15:14] Not used (don’t care). [13:12] Window setting. 00 = rectangular, 01 = Hanning, 10 = flat top, 11 = N/A. 11 SR3, 1 = enabled for FFT, 0 = disable. Sample rate = 20,000 ÷ 2AVG_CNT[15:12] (see Table 28). 10 SR2, 1 = enabled for FFT, 0 = disable. Sample rate = 20,000 ÷ 2AVG_CNT[11:8] (see Table 28). 9 SR1, 1 = enabled for FFT, 0 = disable. Sample rate = 20,000 ÷ 2AVG_CNT[7:4] (see Table 28). 8 SR0, 1 = enabled for FFT, 0 = disable. Sample rate = 20,000 ÷ 2AVG_CNT[3:0] (see Table 28). 7 Power-down between each recording. 1 = enabled. [6:4] Not used (don’t care). [3:2] Storage method. 00 = none, 01 = alarm trigger, 10 = all, 11 = N/A. [1:0] Recording mode. 00 = manual FFT, 01 = automatic FFT, 10 = manual time capture, 11 = real-time sampling/data access. Manual FFT Mode Set REC_CTRL1[1:0] = 00 to place the device in manual FFT mode, which will result in triggering a single FFT cycle. When the spectral record is complete, the device will transmit the data to the ADIS16000 and wait for another start command. Automatic FFT Mode Set REC_CTRL1[1:0] = 01 to place the device in automatic FFT mode. Use the UPDAT_INT and INT_SCL registers to establish the period between “wake-up times,” which triggers data capture, FFT computation and analysis. Manual Time Capture Mode Set REC_CTRL1[1:0] = 10 to place the device into manual time capture mode, which will result in triggering a single time domain data capture. When the device is operating in this mode, 512 samples of time domain data are loaded into the buffer for each axis. This data goes through all time domain signal processing, except the pre-FFT windowing, prior to loading into the data buffer for user access. When the data record is complete, the device will transmit the data to the ADIS16000 and wait for another start command. MEMS ADC PROCESSING DATA BUFFER RECORDS SPI AND REGISTERS Figure 15. Simplified Block Diagram |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |