| 数据搜索系统,热门电子元器件搜索 |
|
AD5665BCPZ-R2 数据表(PDF) 26 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
AD5665BCPZ-R2 数据表(HTML) 26 Page - Analog Devices |
|
26 / 36 page ![]() AD5625R/AD5645R/AD5665R, AD5625/AD5665 Data Sheet Rev. C | Page 26 of 36 Figure 61. I2C Read Operation (14-Lead Package) Figure 62. Placing the AD56x5RBRUZ-2/AD56x5RBRUZ-2REEL7 in High Speed Mode HIGH SPEED MODE Some models offer high speed serial communication with a clock frequency of 3.4 MHz. See the Ordering Guide for a full list of models. High speed mode communication commences after the master addresses all devices connected to the bus with the Master Code 00001XXX to indicate that a high speed mode transfer is to begin. No device connected to the bus is permitted to acknowl- edge the high speed master code; therefore, the code is followed by a no acknowledge. Next, the master must issue a repeated start followed by the device address. The selected device then acknowledges its address. All devices continue to operate in high speed mode until the master issues a stop condition. When the stop condition is issued, the devices return to standard/fast mode. The part also returns to standard/fast mode when CLR is activated while the part is in high speed mode. INPUT SHIFT REGISTER The input shift register is 24 bits wide. Data is loaded into the device as a 24-bit word under the control of a serial clock input, SCL. The timing diagram for this operation is shown in Figure 3. The eight MSBs make up the command byte. DB23 is reserved and should always be set to 0 when writing to the device. DB22 (S) is used to select multiple byte operation. The next three bits are the command bits (C2, C1, and C0) that control the mode of operation of the device. See Table 11 for details. The last three bits of the first byte are the address bits (A2, A1, and A0). See Table 12 for details. The rest of the bits are the 16-/14-/12-bit data-word. The data-word comprises the 16-/14-/12-bit input code followed by two or four don’t care bits for the AD5645R and the AD5625R/AD5625, respectively (see Figure 65 through Figure 67). MULTIPLE BYTE OPERATION Multiple byte operation is supported on the AD56x5R/AD56x5. A 2-byte operation is useful for applications that require fast DAC updating and do not need to change the command byte. The S bit (DB22) in the command register can be set to 1 for 2-byte mode of operation (see Figure 64). For standard 3-byte and 4-byte operation, the S bit (DB22) in the command byte should be set to 0 (see Figure 63). FRAME 2 COMMAND BYTE FRAME 1 SLAVE ADDRESS 19 9 1 SCL START BY MASTER ACK. BY AD56x5 ACK. BY MASTER SDA R/W DB23 A0 A1 A2 1 0 0 A3 DB22 DB21 DB20 DB19 DB18 DB17 DB16 19 9 1 ACK. BY MASTER NO ACK. FRAME 4 LEAST SIGNIFICANT DATA BYTE FRAME 3 MOST SIGNIFICANT DATA BYTE STOP BY MASTER SCL (CONTINUED) SDA (CONTINUED) DB15 DB14 DB13 DB12 DB11 DB10 DB9 DB8 DB7 DB6 DB5 DB4 DB3 DB2 DB1 DB0 SCL 0000 1 X X X 0 0 1 A3 A2 A1 A0 R/W SDA 19 19 NO ACK. SR START BY MASTER ACK. BY AD56x5 HS-MODE MASTER CODE SERIAL BUS ADDRESS BYTE FAST MODE HIGH-SPEED MODE |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |