31 / 99 page ![]() CC2500 SWRS040C Page 31 of 89 Pre-program the PKTLEN register to mod(600,256)=88. Transmit at least 345 bytes, for example by filling the 64-byte TX FIFO six times (384 bytes transmitted). Set PKTCTRL0.LENGTH_CONFIG=0. The transmission ends when the packet counter reaches 88. A total of 600 bytes are transmitted. 0,1,..........,88,....................255,0,........,88,..................,255,0,........,88,..................,255,0,....................... Internal byte counter in packet handler counts from 0 to 255 and then starts at 0 again Length field transmitted and received. Rx and Tx PKTLEN value set to mod(600,256) = 88 Infinite packet length enabled Fixed packet length enabled when less than 256 bytes remains of packet 600 bytes transmitted and received Figure 12: Packet Length > 256 15.3 Packet Filtering in Receive Mode CC2500 supports three different types of packet-filtering: address filtering, maximum length filtering and CRC filtering. 15.3.1 Address Filtering Setting PKTCTRL1.ADR_CHK to any other value than zero enables the packet address filter. The packet handler engine will compare the destination address byte in the packet with the programmed node address in the ADDR register and the 0x00 broadcast address when PKTCTRL1.ADR_CHK =10b or both 0x00 and 0xFF broadcast addresses when PKTCTRL1.ADR_CHK =11b. If the received address matches a valid address, the packet is received and written into the RX FIFO. If the address match fails, the packet is discarded and receive mode restarted (regardless of the MCSM1.RXOFF_MODE setting). If the received address matches a valid address when using infinite packet length mode and address filtering is enabled, 0xFF will be written into the RX FIFO followed by the address byte and then the payload data. 15.3.2 Maximum Length Filtering In variable packet length mode, PKTCTRL0.LENGTH_CONFIG =1, the PKTLEN.PACKET_LENGTH register value is used to set the maximum allowed packet length. If the received length byte has a larger value than this, the packet is discarded and receive mode restarted (regardless of the MCSM1.RXOFF_MODE setting). 15.3.3 CRC Filtering The filtering of a packet when CRC check fails is enabled by setting PKTCTRL1.CRC_AUTOFLUSH =1. The CRC auto flush function will flush the entire RX FIFO if the CRC check fails. After auto flushing the RX FIFO, the next state depends on the MCSM1.RXOFF_MODE setting. PKTCTRL0.CC2400_EN must be 0 (default) for the CRC auto flush function to work correctly. When using the auto flush function, the maximum packet length is 63 bytes in variable packet length mode and 64 bytes in fixed packet length mode. Note that the maximum allowed packet length is reduced by two bytes when PKTCTRL1.APPEND_STATUS is enabled, to make room in the RX FIFO for the two status bytes appended at the end of the packet. Since the entire RX FIFO is flushed when the CRC check fails, the previously received packet must be read out of the FIFO before receiving the current packet. The MCU must not read from the current packet until the CRC has been checked as OK. 15.4 CRC Check There are two different CRC implementations. PKTCTRL0.CC2400_EN selects between the 2 options. The CRC check is different for the 2 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |