16 / 24 page ![]() AD7476/AD7477/AD7478 Rev. F | Page 16 of 24 To exit this mode of operation and power up the AD7476/ AD7477/AD7478 again, perform a dummy conversion. On the falling edge of CS, the device begins to power up, and continues to power up as long as CS is held low until after the falling edge of the tenth SCLK. The device is fully powered up once 16 SCLKs have elapsed and, as shown in , valid data results from the next conversion. If Figure 21 CS is brought high before the tenth falling edge of SCLK, the AD7476/AD7477/AD7478 again goes back into power-down. This avoids accidental power-up due to glitches on the CS line or an inadvertent burst of eight SCLK cycles while CS is low. Although the device may begin to power up on the falling edge of CS, it powers down again on the rising edge of CS as long as it occurs before the tenth SCLK falling edge. Power-Down Mode This mode is intended for use in applications where slower throughput rates are required; either the ADC is powered between each conversion, or a series of conversions can be performed at a high throughput rate and the ADC is then powered down for a relatively long duration between these bursts of several conversions. When the AD7476/AD7477/ AD7478 is in power-down mode, all analog circuitry is powered down. To enter power-down, the conversion process must be interrupted by bringing CS high any time after the second falling edge of SCLK and before the tenth falling edge of SCLK, as shown in . Once Figure 20 CS is brought high in this window of SCLKs, the part enters power-down and the conversion initiated by the falling edge of CS is terminated and SDATA goes back into three-state. If CS is brought high before the second SCLK falling edge, the part remains in normal mode and does not power down. This avoids accidental power-down due to glitches on the CS line. 4 LEADING ZEROS + CONVERSION RESULT CS SCLK SDATA 1 10 16 Figure 19. Normal Mode Operation 110 16 2 THREE-STATE CS SCLK SDATA Figure 20. Entering Power-Down Mode 16 10 1 16 1 A CS SCLK SDATA INVALID DATA VALID DATA THE PART BEGINS TO POWER UP THE PART IS FULLY POWERED UP WITH VIN FULLY ACQUIRED Figure 21. Exiting Power-Down Mode |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |