| 数据搜索系统,热门电子元器件搜索 |
|
AS3687 数据表(PDF) 17 Page - ams AG |
|
|
|||||||||||||||||||||||||||||
AS3687 数据表(HTML) 17 Page - ams AG |
|
17 / 55 page ![]() AS3687/87XM Datasheet www.austriamicrosystems.com/AS3687 1v3-4 16 - 54 Figure 14 – Automatic Mode Switching Charge Pump 1:1, 1:1.5, 1:2 CPOUT C5 1.0µF CURR30 CURR31 CURR32 CURR33 CURR1 CURR2 200mV (curr3x_switch) 450mV (currhv_switch) curr30_on_cp curr31_on_cp curr32_on_cp curr33_on_cp curr1_on_cp curr2_on_cp Debounce Mode Switching 1:1 -> 1:1.5 1:1.5 -> 1:2 cp_mode<1:0> CURR6 curr6_on_cp Battery VBAT C2_P C3 500nF C2_N C1_P C4 500nF C1_N C2 1µF 7.2.2 Soft Start An implemented soft start mechanism reduces the inrush current. Battery current is smoothed when switching the charge pump on and also at each switching condition. This precaution reduces electromagnetic radiation significantly. 7.2.3 Charge Pump Registers Reg. Control Addr: 00h This register enables/disables the Charge Pump and the Step Up DC/DC Converter. Bit Bit Name Default Access Description 2 cp_on 0 R/W 0 = Set Charge Pump into 1:1 mode (off state) unless cp_auto_on is set 1 = Enable manual or automatic mode switching – see register CP Control for actual settings |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |