| 数据搜索系统,热门电子元器件搜索 |
|
AS3687 数据表(PDF) 22 Page - ams AG |
|
|
|||||||||||||||||||||||||||||
AS3687 数据表(HTML) 22 Page - ams AG |
|
22 / 55 page ![]() AS3687/87XM Datasheet www.austriamicrosystems.com/AS3687 1v3-4 21 - 54 DCDC Control 2 Addr: 22h This register controls the Step Up DC/DC Converter and low-voltage current sinks CURR3x. Bit Bit Name Default Access Description 3 stepup_lowcur 1 R/W Step Up DC/DC Converter coil current limit. 0: Normal current limit 1: Current limit reduced by approx. 33% 4 curr1_prot_on 0 R/W 0 = No overvoltage protection 1 = Pull down current on CURR1 switched on, if voltage on CURR1 exceeds 13.75V, and step_up_on=1 5 curr2_prot_on 0 R/W 0 = No overvoltage protection 1 = Pull down current on CURR2 switched on, if voltage exceeds on CURR2 13.75V, and step_up_on=1 6 curr6_prot_on 0 R/W 0 = No overvoltage protection 1 = Pull down current on CURR6 switched on, if voltage on CURR6 exceeds 13.75V, and step_up_on=1 7 step_up_fb_auto 0 R/W 0 = step_up_fb select the feedback of the DCDC converter 1 = The feedback is automatically chosen within the current sinks CURR1and CURR2 (never DCDC_FB). Only those are used for this selection, which are enabled (currX_mode must not be 00) and not connected to the charge pump (currX_on_cp must be 0). 7.3.2 Current Sinks CURR30, CURR31, CURR32, CURR33 These current sinks have a resolution of 8 bits and can sink up to 40mA. The current values can be controlled individually with curr30_current – curr33_current or common with curr3x_strobe or curr3x_preview. Table 9 – Current Sinks CURR30,31,32,33 Parameters Symbol Parameter Min Typ Max Unit Note IBIT7 Current sink if Bit7 = 1 19.2 IBIT6 Current sink if Bit6 = 1 9.6 IBIT5 Current sink if Bit5 = 1 4.8 IBIT4 Current sink if Bit4 = 1 2.4 IBIT3 Current sink if Bit3 = 1 1.2 IBIT2 Current sink if Bit2 = 1 0.6 IBIT1 Current sink if Bit1 = 1 0.3 IBIT0 Current sink if Bit0 = 1 0.15 mA For V(CURR3x) > 0.2V Δm matching Accuracy -10 +10 % CURR30-33 Δ absolute Accuracy -15 +15 % VCURR3X Voltage compliance 0.2 CPOUT V 7.3.2.1 Current Sinks CURR3x Registers Addr: 12h Curr3 control1 This register select the modes of the current sinks30..33 current. Bit Bit Name Default Access Description 0 preview_off_after strobe 0b R/W Select the switch off mode after strobe pulse 0 = normal preview/strobe mode, 1 = switch off preview after strobe duration has expired. To reinitiate the torch mode the preview_ctrl has to be set off and on again |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |