| 数据搜索系统,热门电子元器件搜索 |
|
FP0-IOL 数据表(PDF) 13 Page - Panasonic Semiconductor |
|
|
|||||||||||||||||||||||||||||
FP0-IOL 数据表(HTML) 13 Page - Panasonic Semiconductor |
|
13 / 20 page ![]() Adaptability Program protection Master memory Protected Protected 12 13 Protects your important program by preventing illegal copies GThe combination of upper and lower case alphanumeric characters produces 218 trillion combinations. In addition, after three consecutive entry failures, a power reset is required for password release. I More secure eight-character password can be used along with the previous four-character password. I Program upload is easily prohibited by tool software FPWIN. GReading a program from the PLC main unit is virtually impossible. GIn the upload-prohibited condition, program transfers to the master memory are also prohibited. GRelease of an upload-prohibited condition is possible with a forced release accompanied by a program deletion. GProgram updates are easily carried out by transferring the program in the master memory to FP-X even during an upload-prohibited condition. The transferred program in FP-X is setup with the same upload prohibition and permission conditions used in the master memory. Forced input/output (Original program is required) Ladder monitor (Original program is required) Rewrite during RUN mode (Original program is required) Program download from a PC Data transfer from the master memory Change of data monitor/resistor value Contact monitor Time chart monitor Password protection Program upload to a PC Data transfer to the master memory Items possible during an upload- prohibited condition Items impossible during an upload- prohibited condition High versatility and rich functionality provides “peace of mind” and “flexibility”. * USB port is equipped with C30 and C60. PC PC I An expensive USB conversion adapter/cable is not necessary for connecting a PC to the PLC by using a standard USB port.* USB cable direct connection In the case of FP-X The conventional RS232C port can also be used. AFPX-C30/C60 USB conversion cable RS232C/422 conversion adapter Before Previous Model I The master memory makes a program transfer easy and a real-time clock is equipped also FPWIN GR/Pro FP-X FP-X Master memory To the field operation Program transfer Program transfer Password used ➔ Password locked Upload prohibited set ➔ Upload prohibited Upload prohibited not set ➔ Upload permitted GThe built-in 1 MB flash-ROM can store a 32-kstep program as well as the comments and FPWIN Pro source file. GProgram update in a remote location is easy by simply sending master memory for local installation. GAs the master memory stores the password information, password protection can be applied for program transmission. Similarly, upload prohibition/permission can be setup. GThe built-in real-time clock enables periodical repeated control and periodical data logging. I No need for program backup − easy maintenance GThe programs and comments are stored in flash ROM, requiring no backup batteries. GA backup battery is provided for data and real-time clock (AFPX-BATT) One battery for C14, two for C30 and three for C60 can be attached. A two- battery installation can operate for a long time (10 years or more) without maintenance. (Real-time clock doesn't work without a battery.) Backup battery for FP-X (AFPX-BATT) Connector Battery holder I FROM data storage GFP-X can store a program, comments, a total of 55 words of data, and bit setting values in a flash memory without a battery. All of the data and bits can be stored by adding optional batteries, but writing into a flash ROM is possible without a battery by using applied instructions (F12, P13). Perfectly suited for data storage of the setup values and recipes modified several times a day. Flash-ROM F12 ICRD K0, K1, DT0 During the first scan, read one block (2048 words) from the starting address of DT0 at block number 0. P13 ICWD DT0, K1, K0 When R0 is turned on, write one block (2048 words) starting from the address DT0 at block number 0. * The limitation in a flash ROM designates the number of rewrites to be 10,000, or the feasible number to be approx 30,000. However, rewriting every second will generate a memory failure within a few hours. Reading Writing Programming Note: Product names and company names in this chart are trademarks or registered trademarks of the respective companies. The ladder programming software for FP series −− highly operational software tool for maximizing convenience in the field. Control FPWIN GR for Windows 1. Easy field operations not requiring the use of a mouse for data entry, search, writing, monitoring and timer changes, all carried out only from the keyboard. 2. Allows standard operations in Windows, such as Copy & Paste, etc. 3. All FP series PLCs are supported. The software assets produced by using Ver. 4 or Ver. 3 of NPST-GR are usable. 4. Easy programming with wizard functions. 5. Communication with OPC Server, CommX, GTWIN, PCWAY simultaneously through the same port. I Operational Environment I Features I Accompanying Tools OS Hard disk capacity CPU Onboard memory Screen resolution Display colors Applicable PLC Compatible FP-X version Windows95 (OSR2 or higher)/98/Me/ NT (Ver. 4.0 or later)/2000/XP At least 40 MB Pentium 100 MHz or higher At least 64 MB (depends on OS) At least 1024 × 768 High color (16-bit or higher) FP-X/FP-e/FP0/FP Σ/FP2/FP2SH Relay output type: Ver.2.50 and after Transistor output type: Ver.2.70 and after Tool bar Access often-used functions using icons. Data monitoring window Relay monitoring window Program status display Search window Allows you to search various data Program display Function bar Bottons for command input and confirmation, on-line/off- line selection and PLC mode selection. Successive I/O comments can be input for each device type. Data from Excel and other applications can be copied and pasted via the clipboard. Displays information concerning PLC usage situation and settings, and detailed information when an error occurs. Classified by type, function instructions can be selected from the displayed list. (Simple help included.) Function instruction list Text Compiler Text command input mode Text command input mode I/O comment edit function Status display This software is for importing and exporting programs created in text format to and from FPWIN GR. Programs created on the PLC of another company can be edited as text and then be transferred to the FP Series without difficulty. A ladder diagram is displayed as a mnemonic code is entered from the keyboard. GData Editor This software for the PC is for reading and writing data stored in the memory of FP Series main unit or on an IC card. If a large data table is required in a PLC, the data can be created and edited on a PC and then dowmload to the PLC. GModem connection Communication via modem is easy with FP Series units in isolated locations. GWizard function A Wizard function included in FPWIN GR since versions 2.2 can automatically generate ladder programs by simply entering and selecting required items in the dedicated screen. It can be used to assist in positioning, PID instruction input, and FP-e screen display instruction input. GPersonal preference settings It is possible to switch among preference settings for FPWIN GR, Data Editor and Text Compiler that are set up for different individuals. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |