| 数据搜索系统,热门电子元器件搜索 |
|
FP0-IOL 数据表(PDF) 17 Page - Panasonic Semiconductor |
|
|
|||||||||||||||||||||||||||||
FP0-IOL 数据表(HTML) 17 Page - Panasonic Semiconductor |
|
17 / 20 page ![]() 16 17 Part Number List Related Products List Control FPWIN Pro (IEC61131-3 compliant Windows version software) Programmable Display GT series Control FPWIN GR for Windows *The discontinuation of AFW1031 production is scheduled for August 2007. *The production of FP1, FP-M, FP3/FP10SH has been discontinued. *The production of FP1, FP-M, FP3/FP10SH has been discontinued. FP0 Intelligent Units FP0 Link Units FP0 Expansion Units Product name FP0 E8 Expansion Unit FP0 E16 Expansion Unit FP0 E32 Expansion Unit Number of I/O points Power supply voltage Input Output Connection type Part number Product number Specifications AFP03003 AFP03023 AFP03013 AFP03020 AFP03040 AFP03303 AFP03323 AFP03313 AFP03343 AFP03340 AFP03543 FP0-E8X FP0-E8RS FP0-E8RM FP0-E8YRS FP0-E8YT FP0-E16X FP0-E16RS FP0-E16RM FP0-E16T FP0-E16YT FP0-E32T 8 8 8 8 16 16 16 16 32 Input: 8 Input: 4 Output: 4 Output: 8 Output: 8 Input: 16 Input: 8 Output: 8 Input: 8 Output: 8 Output: 16 Input: 16 Output: 16 − 24 V DC 24 V DC − − 24 V DC − − − 24 V DC Sink/Source ( ±common) 24 V DC Sink/Source ( ±common) − − 24 V DC Sink/Source ( ±common) 24 V DC Sink/Source ( ±common) 24 V DC Sink/Source ( ±common) − 24 V DC Sink/Source ( ±common) − Relay output: 2 A Relay output: 2 A Transistor output: NPN 0.1 A − Relay output: 2 A Transistor output: NPN 0.1 A Transistor output: NPN 0.1 A Transistor output: NPN 0.1 A MIL connector Terminal block Molex connecter Terminal block MIL connector MIL connector Terminal block Molex connecter MIL connector MIL connector MIL connector Notes: 1) The relay output type expansion units come with a power cable (part number AFP0581). (The transistor output type needs no power cable.) 2) The terminal block type relay output units have 2 terminal blocks (9 pins) made by Phoenix. Use a 2.5 mm wide screwdriver. Preferably use the specific terminal block screwdriver (part number AFP0806, Phoenix type code SZS 0. 4 × 2.5 mm) or equivalent. 3) The connector-type relay output units have 2 connectors made by Nihon Molex (Molex type code 51067-0900, 9 pins). Use the specific Molex connector press-fit tool (part number AFP0805, Nihon Molex type code 57189-5000) or equivalent. 4) The transistor output units have a press-fit socket for wire-pressed terminal cable and contacts. Use the press-fit tool (part number AXY52000) for wire-pressed terminal cable. Product name Specifications Part number Product number AFP0420 AFP0421 AFP0480 AFP0401 AFP04121 AFP04123 FP0-TC4 FP0-TC8 FP0-A21 FP0-A80 FP0-A04V FP0-A04I FP0 Thermocouple unit FP0 Analog I/O unit FP0 A/D Converter Unit FP0 D/A Converter Unit K, J, T, R thermocouple, Resolution: 0.1 °C K, J, T, R thermocouple, Resolution: 0.1 °C <Input specifications> Number of channels: 2 channels Input range: 0 to 5 V, –10 to +10 V (Resolution: 1/4000) 0 to 20 mA (Resolution: 1/4000) <Output specifications> Number of channels: 1 channel Output range: –10 to +10 V (Resolution: 1/4000) 0 to 20 mA (Resolution: 1/4000) <Input specifications> Number of channels: 8 channels Input range: 0 to 5, –10 to +10 V, –100 to 100 mV (Resolution: 1/4000) 0 to 20 mA (Resolution: 1/4000) <Output specifications> Number of channels: 4 channels Output range: –10 to +10 V (Resolution: 1/4000) 4 to 20 mA (Resolution: 1/4000) Power supply voltage Product name Specifications Part number Product number FP0 CC-Link Slave unit FP0 I/O Link unit AFP07943 AFP0732 FP0-CCLS FP0-IOL 24 V DC 24 V DC This unit is for making the FP0 function as a slave station of the CC-Link. Only one unit can be connected to the furthest right edge of the FP0 expansion bus. Note: Accuracy will change if an FP0 thermocouple unit is used at the same time. For details, please refer to the FP0 catalog or to the CC-Link Unit manual. This is a link unit designed to make the FP0 function as a station to MEWNET-F (remote I/O system). Related Products FP Σ FP0 . FP-e FP3* . FP10SH FP0 10k FP1* FP2 FP2SH FP-M* FP-X AA A A A AA A A AA A A A AA A A A A A A A N/A N/A N/A A FPWIN GR for Windows Product name Type Part number English: Full type English: Small type English: Ver. up type Chinese Chinese: Ver. up type Korean CD-ROM for Windows CD-ROM for Windows CD-ROM for Windows CD-ROM for Windows CD-ROM for Windows CD-ROM for Windows AFPS10520 AFPS11520 AFPS10520R AFPS10820 AFPS10820R AFPS10920 Applicable PLC A: Available, N/A: Not available A A A A A A A A A A A N/A A A A N/A A N/A FP Σ FP0 . FP-e FP3* . FP10SH FP0 10k FP1* FP2 FP2SH FP-M* FP-X FPWIN Pro for Windows Product name Type Part number English: Full type English: Small type AFPS50550 AFPS51550 CD-ROM for Windows CD-ROM for Windows Applicable PLC A: Available, N/A: Not available GT01: Main Unit STN monochrome LCD STN monochrome LCD STN color LCD GT11: Main Unit GT21C: Main Unit Product name Description Part number 5 V DC 24 V DC 24 V DC 24 V DC RS232C type RS422/RS485 type RS232C type RS422/RS485 type RS232C type RS422/RS485 type RS232C type RS422/RS485 type Black Ash gry Black Ash gry Black Ash gry Black Ash gry Black Ash gry Black Ash gry Black Silver Black Silver AIGT0030B1 AIGT0030H1 AIGT0032B1 AIGT0032H1 AIGT0030B AIGT0030H AIGT0032B AIGT0032H AIGT2030B AIGT2030H AIGT2032B AIGT2032H AIGT2230B AIGT2230H AIGT2232B AIGT2232H Product name Part number Control CommX Ver. 1.3 (OCX for Communication) Control CommX IBM printer port Control CommX USB port Product name FP Web-Server Unit FP Web-Server unit FP Web Configurator Tool AFW20011 AFW20031 Product name Part number Key Unit Economical type is available for secondary key. The key unit is available for PCWAY and Control CommX. Key unit IBM printer port version Key unit USB port version AFW1031* AFW1033 Product name Part number FP Memory Loader Data non-hold type Data hold type AFP8670 AFP8671 Part number AFP0610 AFPS30510 PCWAY Ver. 2.7 (Operation Data Managing Software) Product name Part number PCWAY IBM printer port version PCWAY USB port version PCWAY Version upgrade AFW10011 AFW10031 AFW10401 * Charged version upgrade for Ver. 2.0 to 2.6. Specifications 1. General Specifications 2. Power Consumption, Weight Rated voltage Operating voltage range Rush current Allowed momentary power off time Ambient temperature Storage temperature Ambient humidity Storage humidity Breakdown voltage Insulation resistance Vibration resistance Shock resistance Noise immunity Operating condition EC Directive Compliance Standard Level of contamination Over-voltage category Item Product name Part number AFPX-C14 ❍❍ AFPX-C30 ❍❍ AFPX-C60 ❍❍ AFPX-E16 ❍❍ AFPX-E30 ❍❍ AFPX-EFP0 AFPX-COM1 AFPX-COM2 AFPX-COM3 AFPX-COM4 AFPX-COM5 AFPX-AD2 AFPX-IN8 AFPX-TR8 AFPX-TR6P AFPX-PLS AFPX-MRTC 26 W or less *2 52 W or less *2 64 W or less *2 8 W or less *2 42 W or less *2 0.24 W or less *3 2 W or less *2 2 W or less *2 2 W or less *2 2 W or less *2 2 W or less *2 2 W or less *2 1 W or less *2 1 W or less *2 1 W or less *2 2 W or less *2 2 W or less *2 Approx. 280 g or less Approx. 490 g or less Approx. 780 g or less Approx. 195 g or less Approx. 430 g or less Approx. 65 g Approx. 20 g Approx. 20 g Approx. 20 g Approx. 20 g Approx. 20 g Approx. 25 g Approx. 25 g Approx. 25 g Approx. 25 g Approx. 25 g Approx. 20 g Current consumption Weight Description 100 to 240 V AC (AC power), 24 V DC (DC power) 85 to 264 V AC (AC power), 20.4 to 28.8 V DC (DC power) 40 A or less (C14), 45 A or less (C30, C60) at 25 °C (AC power) 12 A or less at 25 °C (DC power) 10 ms or more 0 to +55 °C -40 to +70 °C 10 to 95% RH (at 25 °C, non-condensing) 10 to 95% RH (at 25 °C, non-condensing) Combined input/output terminals - Combined power and ground terminals, 2300 V AC 1 minute (AC power), 500 V AC*1 1 minute (DC power) Input terminals - Relay output terminals, 2300 V AC*1 1 minute Input terminals - Transistor output terminals, 500 V AC*1 1 minute Power terminals - Ground terminals, 1500 V AC*1 1 minute (AC power), 500 V AC*1 1 minute (DC power) Combined input/output terminals - Combined power and ground terminals, 100 M Ω or higher (500 V DC using an insulation resistance meter) Input terminals - Output terminals, 100 M Ω or higher (500 V DC using an insulation resistance meter) Power terminals - Ground terminals, 100 M Ω or higher (500 V DC using an insulation resistance meter) 5 to 9 Hz, single amplitude 3.5 mm/9 to 150 Hz, constant acceleration 9.8 m/s2, 1 sweep/min, 10 sweeps in each XYZ direction 147 m/s2 1500 V [P-P] pulse width 50 ns, 1 µs (AC power), 500 V [P-P] pulse width 50 ns, 1 µs (DC power) (per noise simulator method) (power terminals) No corrosive gas and no excessive dust Conforming to EN61131-2 2 II Control unit Expansion I/O unit Expansion FP0 adapter FP-X communication cassette FP-X analog input cassette FP-X input cassette FP-X output cassette FP-X pulse I/O cassette FP-X master memory cassette *2 Power consumption by the AC power supply connected to the control unit *3 Power consumption by the DC power supply connected to the expansion FP0 adapter *4 Please refer to FP0 users manual for FP0 expansion units. Please refer to the user manual and specifications for further details. *1 Cutoff current 5 mA |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |