| 数据搜索系统,热门电子元器件搜索 |
|
FP0-IOL 数据表(PDF) 14 Page - Panasonic Semiconductor |
|
|
|||||||||||||||||||||||||||||
FP0-IOL 数据表(HTML) 14 Page - Panasonic Semiconductor |
|
14 / 20 page ![]() Part Number List FP-X Control Unit Product name Part number Specifications Power supply 14 15 Programming Note: Product names and company names in this chart are trademarks or registered trademarks of the respective companies. FP-X C14R Control unit FP-X C30R Control unit FP-X C60R Control unit FP-X C14TD Control unit FP-X C14T Control unit FP-X C14PD Control unit FP-X C14P Control unit FP-X C30TD Control unit FP-X C30T Control unit FP-X C30PD Control unit FP-X C30P Control unit FP-X C60TD Control unit FP-X C60T Control unit FP-X C60PD Control unit FP-X C60P Control unit 8-point input of 24 V DC, 6-point output of 2 A relay Program capacity 16 ksteps, 2-point potentiometer 16-point input of 24 V DC, 14-point output of 2 A relay Program capacity 32 ksteps, 2-point potentiometer, USB port 32-point input of 24 V DC, 28-point output of 2 A relay Program capacity 32 ksteps, 4-point potentiometer, USB port 8-point of 24 V DC, 6-point output of 0.5 A transistor (NPN) Program capacity 16 ksteps, 2-point potentiometer 8-point of 24 V DC, 6-point output of 0.5 A transistor (NPN) Program capacity 16 ksteps, 2-point potentiometer 8-point of 24 V DC, 6-point output of 0.5 A transistor (PNP) Program capacity 16 ksteps, 2-point potentiometer 8-point of 24 V DC, 6-point output of 0.5 A transistor (PNP) Program capacity 16 ksteps, 2-point potentiometer 16-point of 24 V DC, 14-point output of 0.5 A transistor (NPN) Program capacity 32 ksteps, 2-point potentiometer, USB port 16-point of 24 V DC, 14-point output of 0.5 A transistor (NPN) Program capacity 32 ksteps, 4-point potentiometer, USB port 16-point of 24 V DC, 14-point output of 0.5 A transistor (PNP) Program capacity 32 ksteps, 2-point potentiometer, USB port 16-point of 24 V DC, 14-point output of 0.5 A transistor (PNP) Program capacity 32 ksteps, 2-point potentiometer, USB port 32-point of 24 V DC, 28-point output of 0.5 A transistor (NPN) Program capacity 32 ksteps, 4-point potentiometer, USB port 32-point of 24 V DC, 28-point output of 0.5 A transistor (NPN) Program capacity 32 ksteps, 4-point potentiometer, USB port 32-point of 24 V DC, 28-point output of 0.5 A transistor (PNP) Program capacity 32 ksteps, 4-point potentiometer, USB port 32-point of 24 V DC, 28-point output of 0.5 A transistor (PNP) Program capacity 32 ksteps, 4-point potentiometer, USB port AFPX-C14R AFPX-C30R AFPX-C60R AFPX-C14TD AFPX-C14T AFPX-C14PD AFPX-C14P AFPX-C30TD AFPX-C30T AFPX-C30PD AFPX-C30P AFPX-C60TD AFPX-C60T AFPX-C60PD AFPX-C60P 100 to 240V AC 100 to 240V AC 100 to 240V AC 24V DC 100 to 240V AC 24V DC 100 to 240V AC 24V DC 100 to 240V AC 24V DC 100 to 240V AC 24V DC 100 to 240V AC 24V DC 100 to 240V AC FP-X Add-on Cassette FP-X COM1 Communication cassette FP-X COM2 Communication cassette FP-X COM3 Communication cassette FP-X COM4 Communication cassette FP-X COM5 Communication cassette FP-X Input cassette FP-X Output cassette FP-X Analog input cassette FP-X Pulse I/O cassette (for relay output type control unit only) FP-X Master memory with a real-time clock RS232C 1 ch. RS, CS control signal equipped (non-insulated) RS232C 2 ch. (non-insulated) RS485/422 selectable 1ch (insulated) RS485 1 ch. (insulated) + RS232C 1 ch. (non-insulated) Ethernet 1 ch.(10BASE-T, 100BASE-TX) + RS232C 1 ch. (non-insulated) 8 point input of 24 V DC 8 point output of NPN 0.3 A 6 point output of PNP 0.5 A 2 point 12-bit non-insulated 0 to 10 V DC/0 to 20 mA High-speed counter: single-phase 2 ch., each 80 kHz or two-phase 1 ch., 30 kHz. Pulse output: one axis 100 kHz/ch. (Use restriction is applied for a two-unit installation) Master memory: Capable of storing all program steps and comments simultaneously. Storage of FPWIN Pro source files. Real-time clock: Year, month, day, hour, minute, second, day of week (optional battery required) AFPX-COM1 AFPX-COM2 AFPX-COM3 AFPX-COM4 AFPX-COM5 AFPX-IN8 AFPX-TR8 AFPX-TR6P AFPX-AD2 AFPX-PLS AFPX-MRTC Product name Part number Specifications FP-X Options and Service Parts 100 to 240V AC Compliant with international standard IEC61131-3 Programming software approved by PLC Open I Features 1. Five programming languages can be used. Programming can be done using the language most familiar to the developer or using the language most suited to the process to be performed. High-level (structured text) languages that allow structuring, such as C, are supported. 2. Easy to reuse well-proven programs Efficiency when writing programs has been greatly increased by being able to split programming up for each function and process using structured programming. 3. Keep know-how from getting out By “black boxing” a part of a program, you can prevent know-how from leaking out and improve the program’s maintainability. 4. Conversion function for previously written programs provided to allow use of program assets. 5. Uploading of source programs from PLC possible. Maintainability increased by being able to load programs and comments from the PLC. * This only applies to FP-X, FP Σ and FP2 (with comment memory) and to FP2SH and FP10SH (with card board). 6. Programming for all models in the FP series possible. Any model can be used. GMultiple passwords for protection of each block The security level (8 levels) can be input for each block in a program. Only users of a set security level or higher can make changes. Block 1 Control FPWIN Pro (IEC61131-3 compliant Windows version software) GProgramming in the language most suited to the process Easy-to-understand, efficient programs can be created, for example, by using a ladder program for machine control or ST for communications control. GProgramming in the language you are good at Programming time can be greatly reduced by the easy ability to split and then integrate programming for each function and process. I Programming in the most suitable language Main program (SFC) Communications program (ST) Malfunction handling program (ladder) Positioning program (ST) Completed program Completed program Designer A (SFC) Designer B (ST) Designer C (ST) Designer D (ladder) I “Black boxing” of programs Person A (designer) Person B (floor leader) Person C (operator) All blocks Only block 1 Block 1 Block 2 Block 2 Block 4 Block 2 Programming security level Block 1 Low Block 2 Block 3 Block 4 High GRegister time-proven programs by block in the library. GBy using variable identifiers (names), there is no need to be concerned with addresses for each machine when reusing programs. Position Operation Function Modem Connection Function Initialliton Setting Process I Reuse of programs is easy. Parts library New program Positioning program Communications program Malfunction handling program Malfunction handling program Communications program Positioning program Main program I Operational Environment OS Hard disk capacity CPU Onboard memory Screen resolution Display colors Applicable PLC Compatible FP-X version Windows95 (OSR2 or higher)/98/Me/NT (Ver. 4.0 or later)/2000/XP At least 100 MB Pentium 100 MHz or higher At least 64 MB (depends on OS) At least 1024 × 768 High Color (16-bit) or higher FP-X/FP-e/FP0/FP Σ/FP1/FP-M/FP2/FP2SH/FP3/FP10SH Relay output type: Ver.5.1 and after Transistor output type: Ver.5.3 and after (Available soon) FP-X Backup battery FP-X Expansion cable (8 cm) FP-X Expansion cable (30 cm) FP-X Expansion cable (80 cm) FP-X Terminal block Battery for backing up the operation memory and real-time clock Expansion unit connection cable, 8 cm Expansion unit connection cable, 30 cm Expansion unit connection cable, 80 cm Terminal block for C30, C60 and E30, 21 pins, cover with no marking, five units included AFPX-BATT AFPX-EC08 AFPX-EC30 AFPX-EC80 AFPX-TAN1 Product name Part number Specifications FP-X Expansion Unit Power supply 24V DC 100 to 240V AC 24V DC 100 to 240V AC 24V DC Expansion FP0 Adapter FP-X E16R Expansion I/O unit FP-X E30R Expansion I/O unit FP-X E16T Expansion I/O unit FP-X E16P Expansion I/O unit FP-X E30TD Expansion I/O unit FP-X E30T Expansion I/O unit FP-X E30PD Expansion I/O unit FP-X E30P Expansion I/O unit Product name Part number Specifications With an 8cm extension cable and power cable Up to 3 FP0 expansion units can be connected via an adapter. 8-point input of 24 V DC, 8-point relay output of 2 A Remarks; Two or more E16R can't be connected serially because it can't supply the power to other units. With an 8cm extension cable 16-point input of 24 V DC, 14-point relay output of 2 A Remarks; Possible to connect up to 8 units including E16R, EFP0. With an 8cm extension cable 8-point input of 24 V DC, 8-point transistor (NPN) output of 0.5 A Remarks; Two or more E16T cannot be connected serially because it cannot supply the power to other units. With an 8cm extension cable 8-point input of 24 V DC, 8-point transistor (PNP) output of 0.5 A Remarks; Two or more E16T cannot be connected serially because it cannot supply the power to other units. With an 8cm extension cable 16-point input of 24 V DC, 14-point transistor (NPN) output of 0.5 A Remarks; Possible to connect up to 8 units including E16, EFP0. With an 8cm extension cable 16-point input of 24 V DC, 14-point transistor (NPN) output of 0.5 A Remarks; Possible to connect up to 8 units including E16, EFP0. With an 8cm extension cable 16-point input of 24 V DC, 14-point transistor (PNP) output of 0.5 A Remarks; Possible to connect up to 8 units including E16, EFP0. With an 8cm extension cable 16-point input of 24 V DC, 14-point transistor (PNP) output of 0.5 A Remarks; Possible to connect up to 8 units including E16, EFP0. With an 8cm extension cable AFPX-E16R AFPX-E30R AFPX-E16T AFPX-E16P AFPX-E30TD AFPX-E30T AFPX-E30PD AFPX-E30P AFPX-EFP0 |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |