9 / 52 page ![]() DocID026814 Rev 1 9/52 UM1811 Getting started 52 Figure 4. Node connection Once the Open button has been selected (1), the trace window (2) allows checking that the command has been correctly transmitted to the evaluation board. The G3-PLC GUI command panel has as much tab as G3-PLC platforms are connected. To identify the tab, the associated COM port is displayed in the panel title (3). 3.2 Node tree panel The G3-PLC GUI offers access to the “Service Access Points” (SAP) of each layer specified by the G3-PLC standard plus some additional features such as a bootstrap application or the G3 library configuration. Once a G3-PLC platform is connected, it can be explored thanks to the object tree panel. Each root menu can be collapsed or not to see its detailed content. The detailed content gives access to each specific SAP: PHY, MAC, ADP, BOOT and G3LIB. Additional levels of the interface (such as IPv6) may be present. The related functions may be used in conjunction with specific firmware projects that may be obtained from your local support. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|