28 / 64 page ![]() E5 @Z 28 Parameters M M M M M M M M M M M M M M M M M M M a-m P m-sp 0 P 25 C 25 0 C sp-m 0 C ct1 0.0 P lcr1 0.0 P r-s run P al-1 0 C al1h 0 C al1l 0 C al-2 0 C al2h 0 C al2l 0 C al-3 0 C al3h 0 C al3l 0 C o 0.0 P c-o 0.0 P M M M M M M M M M M M M M M M M M M M M M M M cmwt off ct1 0.0 P at off P lcr1 0.0 P hb1 0.0 P hs1 50.0 P sp-0 0 C sp-1 0 C sp-2 0 C sp-3 0 C ins 0.0 C insh 0.0 C p 8.0 C i 233 P d 40 P c-sc 1.00 P c-db 0.0 C of-r 50.0 P hys 1.0 C chys 1.0 C sprt off C ol-h 105.0 P ol-l -5.0 P M M M M M M M psel cwf u-no 1 bps 9.6 len 7 sbit 2 prty even sdwt 20 M M M oapt 0 P icpt 1 P wtpt off P 25 C M insl 0.0 C Power ON Starting in manual mode. Manual control level PID control only PV/MV Press the O Key for at least 1 s Press the O Key for at least 3 s. Displays other than that for switching between automatic and manual. Adjustment Level Press the O Key less than 1 s. Press the O Key less than 1 s. Operation Level AT execute/cancel Communications writing Heater current 1 value monitor Leakage current 1 monitor HS alarm 1 Heater burnout detection 1 SP 0 SP 3 SP 2 SP1 SP used by multi-SP Temperature input shift 1-point shift Set either of these parameters. Upper-limit temperature input shift value 2-point shift Lower-limit temperature input shift value Proportional band Integral time PID settings Derivative time Cooling coefficient Heating/cool- ing Dead band Manual reset value Clear the offset during sta- bilization of P or PD control. Hysteresis (heating) Hysteresis settings Hysteresis (cooling) SP ramp set value MV upper limit MV lower limit Process value Added when Additional PV display is ON. Auto/manual switch PID control only. Added when auto/manual select addition is ON. Press the OKey for at least 3 s. Multi-SP set point setting Heater current 1 value monitor Leakage current 1 monitor RUN/STOP Alarm value 1 Alarm value upper limit 1 Alarm value lower limit 1 Alarm value 2 Alarm value upper limit 2 Alarm value lower limit 2 Alarm value 3 Alarm value upper limit 3 Alarm value lower limit 3 MV monitor (heating) MV monitor (cooling) Press the O and M Keys for at least 3 s. Display flashes. Press the O and M Keys for at least 1 s. Press the OKey less than 1 s Protect Level Communications Setting Level The time taken to move to the protect level can be adjusted by changing the "Move to protect level time" setting. Starting in automatic mode. Process value/ set point Displayed only for models with communications. Changes are effective after cycling power or after a software reset. Operation/adjustment protect Restricts displaying and modifying menus in operation, adjustment, and manual control levels. Initial setting/communications protect This protect level restricts movement to the initial setting, communications setting, and advanced function setting levels. Setting change protect Protects changes to setups by operating the front panel keys. Protocol setting Switches between CompoWay/F (SYSWAY) and Modbus. Communications Unit No. Communications baud rate CompoWay/F (SYSWAY) only Communications stop bits Communications parity Send data wait time Set point during SP ramp Communications data length Some parameters are not displayed depending on the model of the Controller and parameter settings. For details, refer to the E5CZ/E5CZ-U/E5AZ/E5EZ Digital Temperature Controllers User's Manual (Cat. No. H207). |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |