| 数据搜索系统,热门电子元器件搜索 |
|
E5CZ-R2ML 数据表(PDF) 42 Page - Omron Electronics LLC |
|
|
|||||||||||||||||||||||||||||
E5CZ-R2ML 数据表(HTML) 42 Page - Omron Electronics LLC |
|
42 / 64 page ![]() E5EZ-PRR 42 Wiring Terminals • Standard insulation is applied to the temperature gauge's I/O sections. If reinforced insulation is required, connect the input and output terminals to a device without any exposed current-carrying parts, or to a device with standard insulation suitable for the maximum operation voltage of the power supply I/O section. • For E5EZ-PRR@03-model products, in order to satisfy the conduction and emission specifications of EN61326CLASSA, a magnetic ring (TDK: ZAT1730-0730) should be added to the communications line between the K3SC unit and the controller. E5EZ-PRR Nomenclature E5EZ-PRR Alarm Output 1 Alarm Output 2 B B A mA DO NOT USE USE DO NOT 50/60 Hz Potentiometer Communications Communications OPEN 10 Pt 11 6 8 7 9 100 to 240 VAC 1 2 3 4 5 12 EV1 Event Input SD RD SG RS232C RS485 B(+) DO NOT USE 13 14 12 13 14 14 13 12 TC 22 21 20 CLOSE WIPE DO NOT USE Analog Input EV2 V Control Output 1 (OPEN Output) Control Output 2 (CLOSE Output) + + + MANU PV SV MV A M No. 1 Display Operation Indicators Temperature Unit Mode Key Level Key Down Key Up Key No. 2 Display No. 3 Display Automatic/ Manual Key The temperature unit is displayed when parameters are set to display a temperature. The display is determined by the currently selected "temperature unit" parameter set value. c indicates °C and f indicates °F. Displays the process value or parameter type. Lights for approximately one second during startup. Displays the set point, parameter operation read value, or the variable input value. Lights for approximately one second during startup. Displays valve open percentage when valve opening display is on. Nothing will be displayed when valve opening display is switched off. Each press of this key increments the value displayed on the No. 2 display or advances the setting. Holding the key down speeds up the incrementation. Press this key for at least one second to switch between automatic and manual mode. Each press of this key decrements values displayed on the No. 2 display or reverses the setting. Holding the key down speeds up the decrementation. Press this key to move between setting levels. The setting level is selected in the following order: operation level: adjustment level, initial setting level, communications setting level. Press this key to change parameters within a setting level. 1. ALM1 (alarm 1) Lights when alarm 1 output is ON. ALM2 (alarm 2) Lights when alarm 2 output is ON. 2. OUT1, OUT2 (control output 1, control output 2) Lights when control output 1 or control output 2 is ON. 3. STOP (Stop) Lights when operation is stopped. During operation, this indicator lights when operation is stopped by an event or by using the RUN/STOP function. 4. CMW (Communications Writing Control) Lights when communications writing is enabled and is not lit when it is disabled. 5. MANU (Manual Mode) Lights when the auto/manual mode is set to manual mode. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |